21
EXPERT 64+, rev.12
EXPERT 64+
4.7.2. Making the Assignment
You must assign On/Off relays to each output
of the controller. Use provided output stick-
ers to identify the function of each relay on
the faceplate of the controller.
Worksheet are available the end of this
manual to write down your relay assign-
ment settings.
Relays must be assigned separately for
each program in use.
1. Select:
»
12. Setup
»
7. Relay Assignment*
»
Select desired output**
* Only accessible from the installer mode (s.4.2).
** Only the outputs that are enabled in the Setup
menu are available (sec. 4.4).
2. Choose the proper relay then select one
of the following options:
: The relay is assigned to the output;
- - -
: The relay is not assigned to the
output;
TMR
: The load connected to the relay
will run in timer mode (available
for fan/tunnel fan groups only);
OPN :
To assign an opening relay on a
fan/tunnel fan group;
CLO :
To assign an closing relay on a fan/
tunnel fan group.
Proceed in similar fashion to assign the relays
of each output in use (heaters, fan groups,
tunnel fan groups, cooling outputs, tunnel
curtain, vent doors, clock outputs, backup
relay, low pressure alarm relay, lights, and
stir fans).