4.5.4. Probes & Water Meter Cali-
bration
You can slightly adjust the reading of each
probe input in order to obtain accurate and
uniform readings from all probes. In addition,
if a water meter is used, you must calibrate
its water flow rate.
1. Select:
»
9. Advanced Settings
»
12. Probe Calibrations*
* Only accessible from the installer mode (s.4.2).
Probe Calibrations
RH Probe Offset
0 %
SP Probe Offset
.00 “WC
Water Meter 1 Calibration
1 gal/p
Water Meter 2 Calibration
1 gal/p
Out Tem.Probe Offset
0.0 °F
Temp. Probe 1 Offset
0.0 °F
Temp. Probe 2 Offset
0.0 °F
Temp. Probe 3 Offset
0.0 °F
2. Adjust the reading of the probes (if
required).
Relative Humidity Probe —
The reading of the
humidity sensor can adjusted of ±3%.
Static Pressure (SP) Probe —
The reading of
the static pressure probe can adjusted of ±
0.030”WC (±7Pa).
Water Meters —
Set the water flow per pulse
of each water meter. Adjustable from 1 to
100 gallons (or liters) per pulse.
Temperature Probe Offsets —
The reading of
the inside and outside temperature sensors
can adjusted of ±3°F (±1.7°C).
A template is available at the end of this
manual to write down your selection
of sensors.
1. Select
»
9. Advanced Settings
»
11. Probe Assignment*
* This menu is only accessible from the installer
mode (sec. 4.2).
1
2
3
4
5
6
7
8
--- --- --- --- --- --- --- ---
House Temperature Probe Assignment
2. Select the desired assignment menu:
House Temperature;
Tunnel Fans;
Heaters;
Coolings
Attic
Main Breaker.
3. Assign the desired temperature probes to
the selected output: select “ “ to assign a
probe or select “- - -“ for probes that are not
assigned to the output.