4.6.1. Activating the RH Compen-
sation Functions
1. Select:
»
12. Setup
»
3. RH Compensation*
* This menu is accessible if the humidity probe is
activated.
Relative Humidity Compensation
Minimum ventilation?
Yes
Heaters ?
Yes
Use Mist Shutoff?
Yes
Mist on Low R. Humidity?
Yes
2. Set the following parameters:
Minimum Ventilation? —
Select
“Yes”
to en-
able the RH compensation on the minimum
ventilation run time.
Heaters? —
Select
“Yes”
to activate the heat-
ing outputs to compensate for hi humidity
levels.
Mist Shutoff? —
Select
“Yes”
to stop the
cooling outputs when the humidity level is
too high. *
This parameter is accessible if a cooling
output is enabled (sec. 4.4).
Mist on Low R. Humidity? —
Select
“Yes”
to
activate the cooling outputs, according to
a timer, when the humidity level is too low.
*
This parameter is accessible if a cooling output is
enabled (sec. 4.4).
3. RH Compensation with the Cooling
Outputs
• High RH compensation with the mist
cooling output:
the controller can dis-
able the mist output if the RH level gets
higher than the
“Mist Shutoff”
limit.
• Low RH compensation with mist out-
puts:
To compensate for low RH levels,
the controller can activate the misting
output in timer mode. The misting output
starts when RH levels drops below the
“Low RH Set Point”
.