5. TEMPERATURE SET-
TINGS
5.1. House Set Points
5.1.1. Principle of Operation
The house set point is the target tempera-
ture in the room. It is used as the reference
temperature for the activation / deactivation
of the controller’s output and is used as a
reference for the temperature alarms.
In addition, a temperature ramp can be
enabled to obtain an automatic adjustment
of the house set point over a given period
of time. Consequently, the house set point
is always adapted to the animals’ needs as
they grow.
EMPTY ZONE SET POINT:
The
Empty Zone Set Point
is the target room
temperature in the empty zones; the heating
units located in that type of zone operate ac-
cording to this temperature. The empty zone
set point also becomes the target tempera-
ture in the whole house while the controller
is in clean mode. Refer to section 4.9.1 for
further information about the empty zones &
the clean mode.
5.1.2. Settings
1. Select:
»
4. House Set Point
The house set point can only be modified
while the ramp is disabled (sec. 5.2).
Set Point
House Set Point
78.0°F
Empty Zone Temp.
35.0°F
2. Set the following parameters:
House Set Point — This parameter rang-
es from
-40°F to 100 °F (-40.0°C to
37.8°C).
Empty Zone Set Point —
Set the target
temperature used in the non-brood zones.
It ranges from -40°F to 100 °F (-40.0°C
to 37.8°C).