CUBICON Single Plus
User Manual
58
contact point which is auto level shall be attached with exposure. Make sure to calibrate tilt offset as
thick as tape thickness.
Check if the heating bed lamination has not been damaged or the heating bed bending is not serious.
Replace heating bed in the case of heating bed lamination damage or serious heating bed bending.
The heating bed is consumable material and can be replaced through A/S.
7) A part of the model, mostly floor border detach from the floor.
Refer to “6) A model is not attached to a floor (heating bed) and detaching” and take appropriate
measure.
The problem can be solved partially with option such as inside fill density in G-Code formation process.
Material contraction from heat melting printer is the main reason.
Adjust printing condition (extruder, heating bed, printer inside temperature) or use less contracted
materials. Contraction can be improved somewhat depending on material. However model modification
is the most effective method for contraction improvement, which appears by filament solidification as
natural phenomenon.
8) The middle of model is cracked.
This is caused by contraction of the material caused by printer using the thermal melting method.
Adjust printing condition (extruder, heating bed, printer inside temperature) or use less contracted
materials. Contraction can be improved somewhat depending on material. However model modification
is the most effective method for contraction improvement, which appears by filament solidification as
natural phenomenon.
The problem can be solved partially with option such as inside fill density in G-Code formation process
9) The model does not detach from a floor (heating bed)
Wait until heating bed cools off sufficiently. Forceful pull out may harm the heating bed. The model is
attached onto the floor in the heating bed printing process of Cubicon Single Plus. The model can be
detached easily, once the heating bed cools off after printing completion. Proper temperature for the
model detaching is different based on the filament and model model and environment.
In the case of heating bed cannot be detached after heating bed cooled off (cold temperature), try to pull
out the model by pushing its floor part with flat ended object.
In the case of continuous model leftover fixture to the heating bed, the model cannot be detached from
bed as it is attached to fixated leftover. Make sure maintain the heating bed surface tidy.
Replace the heating bed in the case of heating bed lamination damage through A/S.
10) The model is printed partially or it is not printed at all or it is printed abnormally.
Refer to “5) Filament cannot be extruded with nozzle.” and take appropriate measure.
Check printing model and G-Code. Problem may occur in G-Code formation process in the case of
abnormal model. Modify model and try again.
Problem may occur in printing due to printed model and stanchion interruption based on model or
stanchion in use. The problem can be solved in the case of slicing method change (slicing option
adjustment or direction change).
Remove contaminants from inside nozzle.
In the case of continuous problem occurrence although proper model, the nozzle shall be replaced by
A/S.