![CTC Union EcoZenith i555 Pro 1x230V Installation And Maintenance Manual Download Page 85](http://html.mh-extra.com/html/ctc-union/ecozenith-i555-pro-1x230v/ecozenith-i555-pro-1x230v_installation-and-maintenance-manual_2693358085.webp)
85
CTC EcoZenith i555 Pro
Blocking Pool
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
This function is used to block pool heating.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define / Pool" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC)).
In the "Installer/Settings/Pool" menu:
• set the "remote control mode" ("On") in the
"Blocking Pool" row.
Access function scheduling from the "Block. pool,
schedule" row.
For more information, refer to the "Pool" section in the
"Installer/Settings" chapter.
Tariff EL
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
This function is used to block the electric heater during
periods when the electricity rate is higher.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer/Settings/Additional Heat" menu:
• set "remote control mode" ("Yes") in the "Tariff EL"
row.
Access function scheduling from the "Tariff EL" row.
For more information, refer to the "Additional Heat/Tariff
EL" section in the "Installer/Settings" chapter.
Round circulation
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
Round circulation is equipment which an electricity
supplier can fit in order to disconnect, for a short period
of time, equipment which draws high current. The
compressor and electrical output are blocked when
Round circulation is active.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer/Settings” menu:
• Access function scheduling from the "Round
circulation" row.
For more information, refer to the "Round circulation"
section in the "Installer/Settings" chapter.
Menu: "Installer/Settings/Pool".
Activate this function via an external control signal or a weekly
program.
Menu: "Installer / Define / Pool".
Define a mode (Normally Open (NO) or Normally Closed (NC))
for the external control signal.
Menu: "Installer/Settings”. Setting a "Round circulation" weekly
program
Summary of Contents for EcoZenith i555 Pro 1x230V
Page 2: ......
Page 3: ...162 505 72 1 2020 09 22 Installation and Maintenance Manual CTC EcoZenith i555 Pro ...
Page 152: ...152 CTC EcoZenith i555 Pro 18 Wiring diagram relay card 3x400V ...
Page 153: ...153 CTC EcoZenith i555 Pro ...
Page 154: ...154 CTC EcoZenith i555 Pro 19 Wiring diagram relay card 1x230V ...
Page 155: ...155 CTC EcoZenith i555 Pro ...
Page 156: ...156 CTC EcoZenith i555 Pro 20 Wiring diagram relay card 3x230V ...
Page 157: ...157 CTC EcoZenith i555 Pro ...
Page 158: ...158 CTC EcoZenith i555 Pro 21 Wiring diagram for expansion card ...
Page 167: ...167 CTC EcoZenith i555 Pro ...