CTC EcoZenith i555 Pro
10.2
Alarm messages
If a fault occurs with e.g. a sensor, an alarm is triggered. A message appears on the display
with information about the fault.
You reset the alarm by pressing the “Reset alarm” button on the display. If several alarms
are triggered, they are displayed one after the other. A persisting fault must first be rectified
before it can be reset. Some alarms are reset automatically if the fault ceases.
Alarm messages
Description
[E055] Wrong phase order
The compressor motor in the connected heat pump must rotate in the right
direction. The heat pump checks that the phases are connected correctly; if
not, an alarm is triggered. In this case, two of the phases to the heat pump
need to be changed. The power supply to the heat pump must be switched
off when rectifying this fault. This fault generally only occurs during installation.
[Exxx] sensor
An alarm is displayed if a fault occurs with a sensor that is not connected
or has short-circuited and if the value is outside the sensor’s range of
measurement. If this sensor is significant to the system’s operation, the
compressor of the heat pump stops. This requires the alarm to be reset
manually after the fault has been rectified. For the sensors below, the alarm is
reset automatically after correction:
[E002]
Sensor B9 Boiler
[E007]
Sensor B6 Buffer tank
[E012]
Sensor B5 DHW Tank
[E016]
Sensor in to solar panels (B30)
[E017]
Sensor out from solar panels (B31)
[E019]
Sensor pool (B50)
[E020]
Sensor B8 Boiler
[E030]
Outdoor sensor (B15)
[E031]
Primary flow sensor 1 (B1)
[E032]
Primary flow sensor 2 (B2)
[E033]
Primary flow sensor 3 (B3)
[E064]
Return sensor (B7)
[E074]
Room sensor 1 (B11)
[E075]
Room sensor 2 (B12)
[E076]
Room sensor 3 (B13)
[E079]
Sensor solar coil tank (B33)
[E120]
Sensor external boiler (B17)
[E141]
Sensor extra buffer tank upper (B41)
[E142]
Sensor extra buffer tank lower(B42)
[E143]
Sensor external DHW tank (B43)
and for heat pumps 1–3:
[E003] Sensor brine in
[E036] Sensor high pressure
[E005] Sensor brine out
[E037] Sensor discharge
[E028] Sensor HPin
[E043] Sensor low pressure
[E029] Sensor HPout
[E080] Sensor suction gas
Summary of Contents for EcoZenith i555 Pro 1x230V
Page 2: ......
Page 3: ...162 505 72 1 2020 09 22 Installation and Maintenance Manual CTC EcoZenith i555 Pro ...
Page 152: ...152 CTC EcoZenith i555 Pro 18 Wiring diagram relay card 3x400V ...
Page 153: ...153 CTC EcoZenith i555 Pro ...
Page 154: ...154 CTC EcoZenith i555 Pro 19 Wiring diagram relay card 1x230V ...
Page 155: ...155 CTC EcoZenith i555 Pro ...
Page 156: ...156 CTC EcoZenith i555 Pro 20 Wiring diagram relay card 3x230V ...
Page 157: ...157 CTC EcoZenith i555 Pro ...
Page 158: ...158 CTC EcoZenith i555 Pro 21 Wiring diagram for expansion card ...
Page 167: ...167 CTC EcoZenith i555 Pro ...