109
CTC EcoZenith i555 Pro
10. Troubleshooting/Appropriate
i
Avoid placing the
room sensor close to
a stairway due to the
uneven air circulation.
i
If you do not have
radiator thermostats
on the upper floor,
you may need to
install them.
measures
CTC EcoZenith i555 Pro is designed to provide reliable operation and high
levels of comfort, as well as have a long service life. Various tips are given
below which may be helpful and guide you in the event of an operational
malfunction.
If a fault occurs, you should always contact the installer who installed your
unit. If the installer believes the malfunction is due to a material or design
fault, then they will contact Enertech/CTC to check and rectify the issue.
Always provide the product’s serial number.
The heating system
If the set room temperature is not obtained, check:
• that the heating circuit is correctly adjusted and is functioning normally.
That radiator thermostats are open and the radiators are equally warm
all over. Touch the entire radiator surface. Bleed the radiators.
• that CTC EcoZenith i555 Pro is in operation and that no error
messages are displayed.
• that there is sufficient electrical power available. Increase if necessary.
• That the product is not set to the "Max. permitted primary flow
temperature" mode with a too low value.
• that “Inclination” has been set high enough. Increase as required. You
can find out more on this in the "House Heating Curve" chapter. Also
refer to the "Installer/Settings/Heating circuit 1, 2 and 3" menu.
• That the temperature reduction is set correctly.
• that the mixing valve on the EcoZenith is not in the manual position.
If the heat is not even, check:
• That the placement of the room sensors is appropriate for the house.
• That the radiator thermostats don’t interfere with the room sensor.
• That no other heat sources/cold sources interfere with the room
sensor.
• that the mixing valve on the EcoZenith is not in the manual position.
Outdoor sensor/room sensor errors
If a fault occurs with an outdoor sensor, an outdoor temperature of -5 °C
is simulated so that the house does not get cold. An alarm appears in
the display window. If a fault occurs with a room sensor, the EcoZenith
automatically switches to operating according to the set curve. An alarm
appears in the display window.
Resetting after Alarm
You reset the alarm by pressing the reset button on the panel. If several
alarms are triggered, they are displayed one after the other. A persisting
fault must first be rectified before it can be reset. Some alarms are reset
automatically if the fault ceases.
Summary of Contents for EcoZenith i555 Pro 1x230V
Page 2: ......
Page 3: ...162 505 72 1 2020 09 22 Installation and Maintenance Manual CTC EcoZenith i555 Pro ...
Page 152: ...152 CTC EcoZenith i555 Pro 18 Wiring diagram relay card 3x400V ...
Page 153: ...153 CTC EcoZenith i555 Pro ...
Page 154: ...154 CTC EcoZenith i555 Pro 19 Wiring diagram relay card 1x230V ...
Page 155: ...155 CTC EcoZenith i555 Pro ...
Page 156: ...156 CTC EcoZenith i555 Pro 20 Wiring diagram relay card 3x230V ...
Page 157: ...157 CTC EcoZenith i555 Pro ...
Page 158: ...158 CTC EcoZenith i555 Pro 21 Wiring diagram for expansion card ...
Page 167: ...167 CTC EcoZenith i555 Pro ...