![CTC Union EcoZenith i555 Pro 1x230V Installation And Maintenance Manual Download Page 111](http://html.mh-extra.com/html/ctc-union/ecozenith-i555-pro-1x230v/ecozenith-i555-pro-1x230v_installation-and-maintenance-manual_2693358111.webp)
111
CTC EcoZenith i555 Pro
10.1
Information messages
Information messages are displayed when appropriate and are intended to
inform users about various operational situations.
[I013] Start delay
The compressor is not allowed to start too quickly when
it has stopped. The delay is usually at least 10 minutes.
[I002] HC1 Heating off
[I005] HC2 Heating off
[I006] HC3 Heating off
Shows for each heating circuit that the product is
operating in summer mode when only DHW is required,
not heating.
[I011] Round circulation
Indicates that Round circulation is active. Round
circulation is a device which an electricity supplier can
fit with the aim of disconnecting high current draw
equipment for a short period of time. The compressor
and electrical output are blocked when Round circulation
is active.
[I008] Tariff HP off
Indicates that Tariff has switched off the heat pump.
[I010] Tariff EL Off
Shows that tariff has switched off the immersion heater
elements.
[I003] Compressor blocked
The compressor is set to be shut down, e.g. before
drilling or digging has been carried out for the collector
loops. The product comes with the compressor switched
off.
This option is selected in the "Installer/Settings/Heat
Pump 1/2/3" menu.
[I012] High curr., reduced elec.
• The property’s main fuses risk being overloaded
due to, for example, the simultaneous use of
several power-hungry appliances. The product
reduces the electrical heaters’ electrical output
during this period.
• 2h max. 6 kW. Electrical heaters are limited to 6
kW for 2h after switching on. The text is displayed
if >6 kW is required during the product’s first 2
hours of operation. This applies after a power cut
or a new installation.
[I021] Ext. Ctrl Heating HC1
[I022] Ext. Ctrl Heating HC2
[I023] Ext. Ctrl Heating HC3
The remote control affects whether the heating is to
be on or off. If the heating is switched off, "Heating off,
heating circuit 1, 2 and 3" is also displayed.
[I017] SmartGrid: Block
[I018] SmartGrid: Overcapacity
[I019] SmartGrid: Low price
Product functionality is governed by "SmartGrid". Also
refer to the "Installer/Define/Remote Control/SmartGrid"
menu.
[I030] Driver block undervoltage
The heat pump has stopped due to insufficient mains
voltage. The product will attempt to restart.
[I031] Driver block alarm
The heat pump has stopped due to driver failure; for
example, voltage or excessive temperature. The product
will attempt to restart.
Summary of Contents for EcoZenith i555 Pro 1x230V
Page 2: ......
Page 3: ...162 505 72 1 2020 09 22 Installation and Maintenance Manual CTC EcoZenith i555 Pro ...
Page 152: ...152 CTC EcoZenith i555 Pro 18 Wiring diagram relay card 3x400V ...
Page 153: ...153 CTC EcoZenith i555 Pro ...
Page 154: ...154 CTC EcoZenith i555 Pro 19 Wiring diagram relay card 1x230V ...
Page 155: ...155 CTC EcoZenith i555 Pro ...
Page 156: ...156 CTC EcoZenith i555 Pro 20 Wiring diagram relay card 3x230V ...
Page 157: ...157 CTC EcoZenith i555 Pro ...
Page 158: ...158 CTC EcoZenith i555 Pro 21 Wiring diagram for expansion card ...
Page 167: ...167 CTC EcoZenith i555 Pro ...