![CTC Union EcoZenith i555 Pro 1x230V Installation And Maintenance Manual Download Page 147](http://html.mh-extra.com/html/ctc-union/ecozenith-i555-pro-1x230v/ecozenith-i555-pro-1x230v_installation-and-maintenance-manual_2693358147.webp)
147
CTC EcoZenith i555 Pro
Sensor NTC 22k, white cable
Solar sensor PT1000, grey or red cable
(B17) Sensor external boiler
Position: in a sensor pipe or jacket surface on the boiler.
The sensor is connected to the relay card in positions G71 and G72.
Sensor type: NTC 22k
(B30) Sensor in to solar panels
Position: on the return pipe into the solar panels.
The sensor is connected to expansion card X1 in positions 3 and 4.
Sensor type: PT1000
(B31) Sensor, primary flow solar collector
Position: on the pipe out from the solar collectors, as close to the solar
collector as possible, or in a sensor pipe or similar in the solar collector.
The sensor is connected to expansion card X1 at positions 1 and 2.
Sensor type: PT1000, red cable (>150°C)
(B32) Sensor, solar energy charging
Position: on the primary flow from the solar heat exchanger.
The sensor is connected to the circuit card in positions X1 5 and X1 6.
Sensor type: PT1000, grey cable
((B33) Sensor, solar coil
(factory fitted)
Placement: in the tank’s lowest sensor pipe.
The sensor is connected to the circuit card in positions G67 and G68.
Sensor type: NTC 22k
(B41) Sensor, external buffer tank upper
Position: in the sensor pipe or jacket surface on the upper part of the tank.
The sensor is connected to the circuit card in positions X3 9 and X3 10.
Sensor type: NTC 22k
(B42) Sensor, external buffer tank lower
Position: in the sensor pipe or jacket surface on the lower part of the tank.
The sensor is connected to the circuit card in positions X3 11 and X3 12.
Sensor type: NTC 22k
(B43) Sensor, external DHW tank
Position: in the sensor pipe or jacket surface on the external DHW tank.
The sensor is connected to the circuit card in positions X2 7 and X2 8.
Sensor type: NTC 22k
(B50) Sensor, pool
Position: on the return pipe between the pool pump and pool.
The sensor is connected to expansion card X3 in positions 15 and 16.
Sensor type: NTC 22k
Summary of Contents for EcoZenith i555 Pro 1x230V
Page 2: ......
Page 3: ...162 505 72 1 2020 09 22 Installation and Maintenance Manual CTC EcoZenith i555 Pro ...
Page 152: ...152 CTC EcoZenith i555 Pro 18 Wiring diagram relay card 3x400V ...
Page 153: ...153 CTC EcoZenith i555 Pro ...
Page 154: ...154 CTC EcoZenith i555 Pro 19 Wiring diagram relay card 1x230V ...
Page 155: ...155 CTC EcoZenith i555 Pro ...
Page 156: ...156 CTC EcoZenith i555 Pro 20 Wiring diagram relay card 3x230V ...
Page 157: ...157 CTC EcoZenith i555 Pro ...
Page 158: ...158 CTC EcoZenith i555 Pro 21 Wiring diagram for expansion card ...
Page 167: ...167 CTC EcoZenith i555 Pro ...