CTC EcoZenith i555 Pro
Room temp. reduced, Night red °C
-2 (0...-30)
Room temp. reduced, Holiday °C
-2 (0...-30)
The menus are displayed if room sensors are installed
for the heating circuit. The number of degrees by which
the room temperature should be lowered during remote-
controlled night reduction and during holidays can be
set here. Night reduction can also be set periodically;
the temperature decrease is then entered in the weekly
program.
Prim. flow reduced, Night red °C
-3 (0...-30)
Prim. flow reduced, Holiday °C
-3 (0...-30)
The menus are displayed if room sensors are not is
installed for the heating circuit. The number of degrees
by which the primary flow temperature for the heating
circuit should be lowered during remote-controlled night
reduction and during holidays can be set here. Night
reduction can also be set periodically; the temperature
decrease is then entered in the weekly program.
Alarm room temp °C
5 (-40...40)
If the room temperature is too low (according to the set
value), the message "Alarm, low room temp." will be
displayed.
This menu bar is displayed if the room sensor is
connected and defined.
SmartGrid Low price °C
1 (Off, 1...5)
Setting to increase inclination adjustment at energy price
"Low price", via SmartGrid.
Both SmartGrid A and SmartGrid B must be defined in
the remote control menu for this menu to be displayed.
Read more in the "Installer/Define/Remote Control/
SmartGrid A/B" chapter.
SmartGrid Overcapacity °C
2 (Off, 1...5)
Setting to increase inclination adjustment at energy price
"Overcapacity", via SmartGrid.
Both SmartGrid A and SmartGrid B must be defined
with a remote control input for this menu to be
displayed.
Read more in the "Installer/Define/Remote Control/
SmartGrid A/B" chapter.
Example
As a rule, a “Primary flow reduced” reduced value of
3 to 4 °C is equivalent to a reduction of approximately
1 °C in room temperature in a normal system.
i
If room sensors are installed,
the "Room temp lowered..."
menu is displayed. If there are no
room sensors, the "Primary flow
reduced..." menu is displayed.
Summary of Contents for EcoZenith i555 Pro 1x230V
Page 2: ......
Page 3: ...162 505 72 1 2020 09 22 Installation and Maintenance Manual CTC EcoZenith i555 Pro ...
Page 152: ...152 CTC EcoZenith i555 Pro 18 Wiring diagram relay card 3x400V ...
Page 153: ...153 CTC EcoZenith i555 Pro ...
Page 154: ...154 CTC EcoZenith i555 Pro 19 Wiring diagram relay card 1x230V ...
Page 155: ...155 CTC EcoZenith i555 Pro ...
Page 156: ...156 CTC EcoZenith i555 Pro 20 Wiring diagram relay card 3x230V ...
Page 157: ...157 CTC EcoZenith i555 Pro ...
Page 158: ...158 CTC EcoZenith i555 Pro 21 Wiring diagram for expansion card ...
Page 167: ...167 CTC EcoZenith i555 Pro ...