OPERATOR
INTERFACE
SCREENS:
MAIN SCREEN
The main screen displays system status .
The main navigation bar is located at the top of every screen for easy navigation .
System status area includes the following possibilities:
•
Current Wash Phase
– System Idle, Pre-Rinse Running, Caustic Run-
ning, Rinse Running, Acid Running, System Draining, Final Rinse Run-
ning, Sanitizer Running .
•
Current Wash Conditions
– Waiting Cond . SP, Waiting Temp SP, Waiting
Temp & Cond . SP, Wash Conditions Met .
•
Time Remaining
– The time remaining, in seconds, of the current wash
phase . If the timer is not counting down while the system is running,
then the system is waiting for a wash condition such as Temperature or
Conductivity to be met . (See Wash Settings on page 11 .)
If the system is equipped with an electric heater, its icon turns red when
power is supplied to the heater, and displays “Heater On” text above it .
Equipment indicators change color to green when they are open or running .
When the system is sitting idle and there are no active alarms, operators are
allowed a small amount of manual control of the system as long as built-in
interlock criteria are met . Touch the equipment indicator icon you would like
to open or turn on and it will comply if the interlock permissions are met .
Press again to close or shutoff the valve . Refer to our Alarms/Interlocks sec-
tion for more information .
The system auto-maintains its tank level according to the tank settings con-
figured on the Config screen .
•
The water supply to the skid must be capable of filling at the same or
greater rate as the CIP supply pump for effective rinsing . For example,
the standard pump is rated for 50gpm at 50 psi, so the supply water to
the skids should be at least 50gpm to maintain level .
Green indicates
equipment is
open or running
Red indicates
equipment is
closed or stopped