TROUBLE-
SHOOTING
Q. WHAT SHOULD I DO IF THE AUTOMATED VALVES ARE NOT OPERATING?
Ensure that the OSHA Air Dump valve is in the ON position and the supply pres-
sure is over 90psi .
Q. WHAT SHOULD I DO IF I CAN’T RUN THE CIP PUMP?
Check the CIP Supply pump interlocks and ensure all the criteria to operate
have been met .
Ensure the VFD is not faulted and the E-Stop is not inhibiting its operation .
The supply pump can sometimes airlock when the system first starts and the
process lines are dry . Command the current wash to hold and wait for the pump
to stop; then press the resume command . Many times, Hold/Resume clears the
air lock .
Ensure the pump is rotating with the correct rotation and with the system safely
locked out, then ensure the pump impeller spins freely without interference or
resistance .
Q. WHAT SHOULD I DO IF I CAN’T RUN THE HEATER?
Verify that the supply flow is greater than 10 GPM, which is a safety feature that
ensures enough water flow for the heater to run .
Ensure the control system temperature setpoint is set on the desired tempera-
ture and that the return temp is lower than that value .