8
CONTACT CSI FOR MORE INFORMATION | CSIDESIGNS.COM | [email protected] | +1.417.831.1411
OPERATION
CONTROL PANEL
Use the touchscreen control panel to select wash parameters and cleaning cycle .
Operators should take a moment to familiarize themselves with the items in bold
below .
SYSTEM START
1 . Verify all Swing, Hose, and Piping Connections are secure .
2 . Verify the
Air Relief Valve
is in the
On
position .
3 . Verify the
E-Stop
is not activated .
4 . To change wash parameters, press the
Config
button . On the user login
screen—
a . Input your username and password .
b . Default login to change configuration parameters:
User: engineer
Pass: engineer
c . Adjust wash settings (e .g ., Temperature, Flow, Chemical Concentration)
d . Make the desired configuration changes and press the Logoff button .
5 . To start the system, ensure it is fully connected in a safe manner and press
the
Commands
button . The system presents the available washes .
a . Select the desired wash type on the left
b . Press the
Start
button on the right .
c . Press the
Abort
button to stop and cancel the current wash if needed
during the wash .
d . Press the
Hold
button to pause the current wash sequence and keep its
current position and time remaining . Press the
Restart
button to resume
operation .
6 . When the system is started, it automatically opens the water fill valve and
maintains tank level according to Tank settings located on the
Config
screen .
7 . The system continues to run in Automatic mode until the Operator stops
the system by pressing the
Abort
button,
Hold
button,
E-Stop
button, or the
system goes into an Alarm state .
a . If the system goes into Alarm, the issue that caused the alarm must be
resolved before continued operation .
b . Transmitter errors and tank low level limit alarms are indicated on the
screen by a yellow rectangle warning symbol and will auto-acknowl-
edge themselves once the problem has been resolved .
Displays when
there is a
transmitter error
or tank low level
limit alarm
Displays when
a piece of
equipment is
in an alarm state