14
CONTACT CSI FOR MORE INFORMATION | CSIDESIGNS.COM | [email protected] | +1.417.831.1411
OPERATOR
INTERFACE
SCREENS:
CONFIG
SCREEN
SYSTEM OPTIONS
These are set at the factory with the options purchased with the system .
When
Has Plant Integration
is configured, the button will turn green (not
blue) and will enable communication between skid and plant via ethernet . When
Standalone System
is configured, the button will turn blue (not green) and does
not allow communication via ethernet .
Has Electric Heater
– Allows the system to heat and maintain temperature
during the Caustic and Acid phases of the wash cycle .
Has Caustic Pump
– Allows automated chemical dosing of Caustic during
the Caustic wash phase .
Has Acid Pump
– Allows automated chemical dosing of the Acid during the
Acid wash phase .
When
Caustic Dosing by Time
is configured, the button will turn green (not
blue) and the “Caustic Pump Runtime” numeric entry box will appear . When
Caustic Dosing by Conductivity
is configured, the button will turn blue (not
green) and the “Caustic Pump Runtime” numeric entry box will disappear .
When
Acid Dosing by Time
is configured, the button will turn green (not
blue) and the “Acid Pump Runtime” numeric entry box will appear . When
Acid
Dosing by Conductivity i
s configured, the button will turn blue (not green) and
the “Acid Pump Runtime” numeric entry box will disappear .