SERENITY – technician Guide
60
Address Description
Default
signals will be reported to a Monitoring Station
All others - On
P219E
Report Stay Mode Arm-Disarm
-
If this option is on then all
Stay Mode Arm/Disarm signals will be reported to a Monitoring
Station
Enable
P220E
Report Disarm only after an Activation
-
If this option is on,
the panel will not normally send an Arm/Disarm signal to the
monitoring company, however, if a zone alarm occurs then the
panel will send a Disarm following the disarming of the panel to
show it has been turned off by a valid user
Disable
P221E
Report Stay Mode Disarm only after an Activation
-
If this
option is on, the panel will not normally send a Stay Mode
Arm/Disarm signal to the monitoring company, however, if a
zone alarm occurs then the panel will send a Stay Mode Disarm
following the disarming of the panel to show it has been turned
off by a valid user
Disable
P222E
Report Access to Program Mode
-
If this option is on the
panel will report a Contact ID code to indicate that either User or
Installer program Modes have been accessed
Channels
3,4,5,7 – Off
All others - On
P223E
Report Zone Restores
-
If this option is on the panel will report
all zone restores. If this option is turned off the panel will only
report the alarms
Channels
3,4,5,7 – Off
All others - On
P224E
Report Delinquent
-
If the panel has been configured for
Delinquency monitoring
[P76]
and an area has not been armed
for the time set at [P76], a Delinquency Alarm will be sent to the
Monitoring Station
Channels
3,4,5,7 – Off
All others - On
P225E
Report Fuse Failure
-
The panel has two on-board thermal
fuses designed to protect the 12v DC outputs from short circuits.
If this option is on and either of these fuses are open, a report
will be sent to the monitoring station if Contact ID is set as the
reporting format
Enable
P226E
Report Radio Battery Low
-
If this option is on the panel will
report a Battery Low from any radio zones that have the battery
status monitored
Channels
3,4,5,7 – Off
All others - On
P227E
Report Supervised Radio Alarm
-
If this option is on the panel
will report a Supervised radio Alarm (see
[P125]
)
Channels
3,4,5,7 – Off
All others - On
P228E
Report Zone Sensor-watch Alarm
-
If this option is on the
panel will report a Zone Inactivity (Sensor-watch) Alarm (see
[P176]
)
Channels
3,4,5,7 – Off
All others - On
P229E
Report Latchkey Disarm
-
When this option is turned on and
the panel was armed in Latchkey Report Mode, at disarm by
non-latchkey user the specified latchkey disarm report will be
send via voice or SMS report channel to user, marked as
latchkey mode user (
[P8]
).
Channels 3,4–
On
All others - Off
P230E
Report communication (RF) Interference Detected
-
If the
radio receiver detects RF Interference (Jamming) of the radio
frequency, the panel can report this event to the monitoring
station if this option is turned on
Channels
3,4,5,7 – Off
All others - On
P231E
Report Output Fail
-
If this option is on and a fault is detected
on the output, a report will be sent to the monitoring station if
Contact ID is set as the reporting format
Channels
3,4,5,7 – Off
All others - On