2.1: Outputs/Output Type
Address
Description
Default
P46E
Steady Output
-
The output will change its state when an
alarm occurs
Enable
P47E
Single Pulse Output
-
This option produces a single pulse at
the output when an alarm occurs (the pulse time is the value
programmed at address
[P61]
).
Disable
P48E
Flash Output
-
When the output is turned on this option
causes the output to flash at a rate set at address
[P61]
. One
use is to flash a lamp during an alarm.
Disable
2.2: Outputs/User Assignment
Address Description
Default
P1015E
User code turns this output on
-
Any user can be allowed to
turn an Output ON. This Function can be used to control
external devices via the panel keypad with a User assigned to
that Output. Once an Output is turned ON by a User, the
Output can turn OFF again automatically if a reset time is
assigned to the Output, or it can be turned off by the same user
or by a different user with the next program location.
Disable
P1016E
User code turns this output off
-
Any user can be allowed to
turn an Output OFF. This Function can be used to control
external devices via the panel keypad with a User assigned to
that Output. Once an Output is turned OFF by a User, the
Output can be turned on by the same user or by a different
user with the previous program location
Disable
2.3: Outputs/Time Zone Assignment
Address Description
Default
P1192E
Time Zone Assignment
-
If a time-zone is assigned to an
output it will turn the output on when the time-zone starts and
turn the output off when it finishes.
Disable
2.4: Outputs/Keypad Assignment
Address Description
Default
P1098E
Keypad is linked to Output
-
A Keypad can be assigned to an
Output or multiple Outputs. If a Keypad is not assigned to an
Output a User cannot turn that Output On or Off from the
Keypad. This feature is useful when using the access control
features of the panel, eg a User may be allowed to operate
more than one Output with their code but they will be limited to
just the Output assigned to the Keypad they are using
Disable
2.5: Outputs/Signals to Output
Address Description
Default