Address Description
Default
rights of specified user(s) ([P19]). There are 8 time-zones that
can be programmed.
P188E
Time Zone Day
-
The Time-zone days are the days of week that
the time-zone will be active. You can select any combination of
the days from Sunday till Saturday. There are 8 time-zones that
can be programmed.
Disable
P189E
Time Zone Password
-
When this option is not empty then
time-zone is inactive until user enters valid password. After that
time-zone behaves like an ordinary time-zone. By entering valid
password once again user will deactivate time-zone. When time-
zone start time expires then area(s) assigned to time-zone will
arm after a 2 sec delay.
Disable
P190E
Holidays
-
It is possible to pre-program up to 8 holidays.
Holidays can override the time-zone function on the
programmed day. For example, if an output was automatically
controlled by a time- zone, the pre-programmed holidays can
stop the output from turning on or off on a holiday. A holiday
consists of a single day programmed by date. The holiday begins
at the start of the day (00:00:00) and finishes immediately
before midnight (23:59:59) on the programmed date. Holidays
can be programmed in any order (although for simplicity it is
recommended that they are programmed in chronological order)
and the panel automatically removes them once the day ends. If
you wish to remove a programmed holiday you should to clear
the date field.
Disable
8.1: Time Zones/Area Assignment
Address Description
Default
P191E
Time Zone Assigned to Area
-
If area assigned to time-zone if
will automatically armed when time-zone starts and disarmed
when it finishes. You can assign more than one time-zone to
each area. If assigning multiple time-zones you should insure
that they do not overlap as this could cause confusion.
Disable
P53E
Time Zone Stay Armed Area -
The parameter is used for the
separation time zone possibility to made ARM and STAY ARM
operations. If the parameter marked when time zone will start,
the corresponded area will STAY armed. Otherwise, when time
zone will start the area will ARMED.
Disable
8.2: Time Zones/Output Assignment
Address Description
Default
P192E
Time Zone Assigned to Output
-
If a time-zone is assigned to
an output it will turn the output on when the time-zone starts
and turn the output off when it finishes.
Disable
8.3: Time Zones/User Assignment
Address Description