![Crow serenity Technician'S Handbook Download Page 34](http://html1.mh-extra.com/html/crow/serenity/serenity_technicians-handbook_2689363034.webp)
SERENITY – technician Guide
34
Address Description
Default
turn on
P12E
Access Tag User
- Access Tag can be used to Arm/Disarm all
or part of the alarm or it can be used to operate outputs for
access control purposes.
Disable
P13E
Remote Control User
- This option defined user rights for
remote control of the control panel via phone line by DTMF
control code numbers, via SMS or via WEB-server and
smartphone application.
User 1 only
1.4: Users/Areas Assignment
Address Description
Default
P14E
User Assigned To Area
- If a User has this option on, they can
Arm/Disarm all zones assigned to Area
all users
assigned to
area 1
1.5: Users/Output Assignment
Address Description
Default
P15E
User code turns output on
-Any user can be allowed to turn
an Output ON. This Function can be used to control external
devices via the panel keypad with a User assigned to that
Output. Once an Output is turned ON by a User, the Output can
turn OFF again automatically if a reset time is assigned to the
Output, or it can be turned off by the same user or by a
different user with the next program location
Disable
P16E
User code turns output off
-Any user can be allowed to turn
an Output OFF. This Function can be used to control external
devices via the panel keypad with a User assigned to that
Output. Once an Output is turned OFF by a User, the Output
can be turned on by the same user or by a different user with
the previous program location
Disable
1.6: Users/Keypad Assignment
Address Description
Default
P18E
User can operate at keypad
-Any user can be assigned to
only operate certain Keypads. This option controls whether a
code or access tag User can Arm/Disarm from certain keypads.
This option does not restrict users from operating outputs from
a particular keypad (this is done at location
[P98]
)
Enable
1.7: Users/Time Zone Assignment
Address Description
Default
P19E
User Controlled by Time Zone
- When the user is controlled
by time zone, its keypad code, access tag and pendant
deactivated all the time, when the time zone is not started or
finished. Only when the time zone is started, the user can
perform actions in the system in accordance with its rights as
Disable