2.6: Outputs/Timing
Address Description
Default
P60E
Output Delay Time
-
The 'On' delay allows the operation of the
Output to be delayed by the time programmed at this location.
If set to '0' there will be no on delay and the Output will operate
the instant it is turned on. The time range is 0-36000 seconds.
0s
P61E
Output Pulse Time
-
Output Pulse Time affects the time an
output turns on when the pulse timer is used on the Output
(see
[P47]
, [P48]). The pulse time is in 1/10th second
increments so that very quick timing can be achieved. The
maximum value that could be assigned to is 36000 which
corresponds to 1 hour. The parameter valid for wired outputs
only.
20
P62E
Output Reset Time
-
The Reset time affects the time the
output turns on in case of alarm state. The time range is 0-
36000 seconds
For outputs 1
and 2, 240
sec, all the
rest outputs
endless
P63E
Output Chime Time
-
The Chime Mode time affects the time
the output turns on when a Chime Zone is activated. The Chime
time is in 1/10th second increments so that very quick timing
can be achieved.
Min 0 max 36000
20
2.7: Outputs/Radio Output
Address Description
Default
P64E
Learn Radio Output
-
Save new radio output in memory
Disable
P65E
Find Radio Output
-
Find existing radio output in memory
Disable
P66E
Delete Radio Output
-
Delete existing radio output from
memory
Disable
P184E
Output reset config-
This function resets to default
parameters values which were defined in (P185E) of a radio
output.
P185E
Output config -
This function set remotely the radio output
parameters such as led on/off, sounder on/off, led and sounder
timeouts, etc.
2.8: Outputs/Output Name
Address Description
Default
P67E
Output Name
-
Set output name
,
up to 16 characters
"output #"
3:
Areas
3.0: Areas/Settings
Address
Description
Default
P68E
Code required to bypass zones
-
If this option is turned on,
the BYPASS button cannot access Bypass Mode directly. To
Disable