Serenity Quick Programming Guide
The default settings of this panel have been chosen to allow the system to be up and
running with a minimum of programming. As a result, there are normally only a handful
of program definitions that need to be changed to get the system fully functional.
Thinking of the immediate needs of the customer, we created the "Quick
Programming" as a way to quickly set up the Serenity system.
Note: Quick programming menu covers selected parts of the programming options in
the Serenity. To access all options, you will mostly need Installer mode (for more
details, see the "Installation Summary Tables" section of the guide)
Note: you can always return the system to factory default from installer programming level
(see address P340E)
Programming the Unit
Important Notice
: Installer can choose whether he/she wishes to use the quick
programming through the main menu as described previously in this manual (see
How
to enter to quick programming mode
on page 14) or to use the address command
directly as will be shown in the "Installation Summary Tables" section. Installer may use
the following recommended steps sequence or can select specific requested steps
according the installation type.
!!!!!! Note: By default there are no detectors assigned or learned in the control panel, so
any attempt of arming the system will be denied until a detector is learned
Quick Programming mode: Main menu
Quick Programming
000000
Enter
Step 1: Program the Installer Code
Address Description
Default
P310E
Installer Code
-
This code is used to enter full Installer
Programming mode. The default installer code is 000000. The
Installer Code must be between 4-8 digits in length if parameter is
enabled in (P327)
The default
installer code
is 000000
Step 2: Set the System Date & Time
Address Description
Default
P120E
System Date
-
The Real Time Clock controls the Time-zones,
the timing of automatic test connections and is used to Time
and Date stamp the events in the Event Buffer.
Ensure this is set
correctly at the time of installation so that
the functions affected by it
will work properly
. The clock is programmed in 24 hour format (e.g.
00:00-23:59)
Disable
Step 3: Report Channels Type
Installer should choose and enable the report channel type
Address Description
Default
P195E
CID PSTN -
Set channel type as ContactID PSTN. Need to set
PSTN enabled to use this type of channel. Default assignment:
channels 1,2 - ContactID PSTN, channels 3,4,5 - voice message
(see
Description)