53
Address Description
Default
P159E
Zone tamper assigned to output
-
Zone tamper can trigger
selected output(s) for local alarm signaling.
All Zones
Assigned to
outputs 1&2
P160E
Chime zone alarm assigned to output
-
If a zone is
programmed as a Chime zone
[P142]
and it activates, the zone
can trigger selected Outputs for local alarm signaling. The
output will operate for the Chime to Output time at location
[P63]. The zone must clear before the output can be activated
again
Disable
P161E
Armed zone entry delay assigned to output
-
If the alarm is
Armed and a delay zone triggers the entry delay it can also
turn an Output on to warn that the entry delay is counting
down and the alarm should be turned off
Disable
P162E
Stay mode entry delay assigned to output
-
If Stay Mode is
Armed and a delay zone triggers the entry delay it can also
turn an Output on to warn that the entry delay is counting
down and the alarm should be turned off
Disable
P163E
Zone near alarm assigned to output -
If zones are
programmed for near and verified alarms
[P73]
, it is also
possible to get an indication of a near alarm from any of the 16
outputs using this program location. A near alarm is the first
alarm during an armed period
All Zones
Assigned to
outputs 1&2
P164E
Zone verified alarm assigned to output
-
If zones are
programmed for near and verified alarms
[P73]
, it is also
possible to get an indication of a verified alarm from any of the
16 outputs using this program location. A verified alarm is the
second alarm from a different zone to the one that caused the
near alarm and must happen within 45 minutes of the near
alarm
All Zones
Assigned to
outputs 1&2
7.6: Zones/Beeps to Keypad
Address Description
Default
P165E
Armed Zone Alarm Beeps to Keypad
-
If an Area is Armed
and a zone assigned to that Area activates, the zone can sound
the buzzer at selected keypads for local alarm signaling. This
location assigns zone alarm beep to a keypad for alarms that
occur when in the Full Armed State.
Enable
P166E
Stay Mode Zone Alarm Beeps Keypad -
If an Area is Stay
Mode Armed and a zone assigned to that Area activates, the
zone can sound the buzzer at selected keypads for local alarm
signaling. This location assigns zone alarm beep to a keypad for
alarms that occur when in Stay Mode is Armed
Enable
P167E
Zone 24 hour alarm beeps to keypad -
If a zone is
programmed as a 24 Hour type and it activates, the zone can
sound the buzzer at selected keypads for local alarm signaling.
If the zone is a standard 24 hour type
[P139]
or Fire type
[P141] the keypad buzzer will sound until reset by a User but if
it is an Auto-reset type [P140] the keypad buzzer will reset
when the input clears
Enable
P168E
Chime Zone Alarm Beeps Keypad -
If a zone is programmed
as a Chime zone and it activates, the zone can sound the
Enable