SERENITY – technician Guide
50
7:
Zones
7.0: Zones/Status
Address Description
Default
P129E
Zone is active -
Zone will be monitored by the panel.
Disable
P130E
Stay mode zone-
Zone will cause alarm if triggered when Stay
Mode is armed. This feature is normally used for arming just
part of the alarm at night time.
Enable
P131E
Two trigger zone-
If this option is on the zone will have to
trigger twice within the two trigger time
[P126]
before it will
cause an alarm. If the zone does not trigger a second time
before the two trigger time expires, the count is reset and it will
take another two triggers to cause an alarm on this zone. If
more than one zone is set-up as a two trigger zone, then a
single trigger from two separate zones within the two trigger
time can also cause an alarm. If the zone becomes faulty and
still open once triggered at end of two trigger time period it will
also cause an alarm.
Disable
P132E
Exit delay zone-
Zone should be closed for ready to arm. It
will not cause an instant alarm if triggered during the exit delay
time.
Enable
P133E
Can Arm if Zone is not Ready-
Zone can remain open during
arming and will cause alarm in case it will remain open after the
exit delay expired.
Zone 1 & 2 only
P134E
Handover zone-
A Handover Zone is one that its entry delay
will apply provided a Non-Handover entry zone is triggered
first. If no other entry delay zones are triggered before the
handover zone the entry delay on that zone does not apply and
the alarm will become instant (no entry delay)
Zone 2 only
P135E
Manually bypassed zone-
Zone can be manually bypassed at
the keypad while in the disarmed state. Once the area with the
bypassed zone has been armed and then disarmed, the manual
bypass is removed and the zone must be manually bypassed
again before arming if required.
Enable
P136E
Auto bypassed zone-
Zone will be auto-bypassed if unsealed
at the expiry of the exit delay. If a zone is unsealed at the time
of arming and remains unsealed when the exit delay expires
and this option is on for that zone it will be automatically
bypassed by the panel. If the zone seals after that time it will
be re-instated automatically and can then cause an alarm. On
disarming of the alarm any auto-Bypasses are removed
Disable
7.1: Zones/Area Assignment
Address Description
Default
P137E
Zone assigned to area-
This option assigns the Zone to Area.
If a Zone is assigned only to one area it will activate if specified
area is armed. If zone assigned to more than one area it will
activate only when all assigned areas are armed. By default all
zones assigned to Area 1.
(see
Description)