7.2: Zones/Working Mode
Address Description
Default
P138E
Zone is normal
-
Zone without any special behavior.
Enable
P139E
Zone is 24 hour zone
-
If this option is on the zone will be
constantly monitored regardless of the arm/disarm state of the
panel. If the 24 Hour zone also has an entry delay programmed
[P174]
, this delay will apply. If the 24 Hour zone activates but
then resets before the entry delay expires no alarm will be
generated. Once the alarm has been generated it must be
cleared by entry of a valid User code
Disable
P140E
Zone is 24 hour auto-reset zone
-
If this option is on the
zone will be constantly monitored regardless of the arm/disarm
state of the panel. Once an alarm has been generated with a 24
Hour Auto-reset zone, the alarm will be reset automatically
once the zone is closed. If the 24 Hour zone also has an entry
delay programmed
[P174]
, this delay will apply. If the 24 Hour
zone activates but then resets before the entry delay expires no
alarm will be generated. This feature can be useful for
monitoring plant type alarms such as freezer alarms.
Disable
P141E
Zone is 24 hour fire zone
-
If this option is on the zone will be
constantly monitored regardless of the arm/disarm state of the
panel. If the 24 Hour Fire zone also has an entry delay
programmed
[P174]
, this delay will apply. If the 24 Hour Fire
zone activates but then resets before the entry delay expires no
alarm will be generated. Once the alarm has been generated it
must be cleared by entry of a valid User code.
Disable
P142E
Chime zone
-
If this option is on, the zone will operate Chime
mode when disarmed. When the alarm is armed the Chime
Mode is disabled for this zone. A Chime zone can sound the
keypad buzzer or operate an output to indicate that the zone is
unsealed. It is normally used to monitor areas during the
daytime
Disable
P143E
Permanent chime zone
-
If this option is on, the zone will
operate Chime mode when armed or disarmed. When the alarm
is armed the zone will continue to only be a Chime Mode Zone
and will not cause a burglar alarm. A Chime zone can sound the
keypad buzzer or operate an output to indicate that the zone is
unsealed
.
Disable
7.3: Zones/Options
Address Description
Default
P144E
Zone will not report 24 hour alarm
-
If this option is turned
on and the zone is set as a 24 Hour type, when an alarm is
generated, the alarm will not be transmitted to the monitoring
station via the dialler
Disable
P145E
Zone in Bypass Group
-
Zone belongs to bypass group. Zones
that have been assigned to the group could be bypassed
simultaneously.
Disable
P146E
Zone Sends Reports
-
this option enables the zone send report
function through all enabled communication channels
Enable