![Crow serenity Technician'S Handbook Download Page 46](http://html1.mh-extra.com/html/crow/serenity/serenity_technicians-handbook_2689363046.webp)
SERENITY – technician Guide
46
Address
Description
Default
to just the Output assigned to the Keypad they are using
4.4: Keypads/Alarm to Outputs
Address Description
Default
P59E
Keypad Panic Alarm to Output
-
A Keypad Panic Alarm
(pressing C & D buttons together) can be assigned to an Output
or multiple Outputs. This can be used to operate an audible or
visual alarm connected to the Output
Outputs
1,2,11-16
P99E
Keypad Fire Alarm to Output
-
A Keypad generated Fire
Alarm (pressing the A & B) can be assigned to an Output or
multiple Outputs. This can be used to operate an audible or
visual alarm connected to the Output
Outputs
1,2,11-16
P100E
Keypad Medical Alarm to Output
-
A Keypad generated
Medical Alarm (pressing the B & C) can be assigned to an
Output or multiple Outputs. This can be used to operate an
audible or visual alarm connected to the Output
Outputs
1,2,11-16
P101E
Keypad Tamper Alarm to Output
-
If the keypad has a
Tamper Switch fitted and this switch is activated, the Tamper
Alarm can be assigned to an Output or multiple Outputs. This
can be used to operate an audible or visual alarm connected to
the Output
Disable
Note: not
relevant to
keypad 1 which
is control panel
keypad
P102E
Wrong Code Alarm to Output
-
If someone is attempting
disarm the alarm by trying various code combinations and they
enter in 5 wrong codes the panel will go into a 'Wrong Code'
tamper alarm. The Alarm can be assigned to an Output or
multiple Outputs. This can be used to operate an audible or
visual alarm connected to the Output. A correct code entry will
reset the tamper alarm
Disable
4.5: Keypads/Beeps to Keypads
Address
Description
Default
P103E
Mains Fail Beeps Keypad Buzzer
-
If this option is on a Mains
Failure will cause the keypad buzzer to sound continuously. The
continuous beep will automatically clear when the Mains returns
to normal or it can be silenced by pressing the ENTER button on
the keypad
Disable
P104E
Fuse Failure Beeps Keypad Buzzer
-
If this option is on a
Fuse Failure (12v DC output short) will cause the keypad buzzer
to sound continuously. The continuous beep will automatically
clear when the short is removed and the fuse returns to normal
or it can be silenced by pressing the ENTER button on the
keypad
Enable
P105E
Battery Low Beeps Keypad Buzzer
-
If this option is on a
Panel Battery Low will cause the keypad buzzer to sound
continuously. The continuous beep will automatically clear when
the battery returns to normal or it can be silenced by pressing
the ENTER button on the keypad
Enable