![Cray ClusterStor L300 Installation Manual Download Page 63](http://html1.mh-extra.com/html/cray/clusterstor-l300/clusterstor-l300_installation-manual_2680121063.webp)
[admin@sn11100n000 ~]$
cscli fs_info
----------------------------------------------------------------------------------------
OST Redundancy style: Traditional Array parity (MDRAID)
Disk I/O Integrity guard (ANSI T10-PI) is not supported by hardware
----------------------------------------------------------------------------------------
Information about "sn11100" file system:
----------------------------------------------------------------------------------------
Node Role Targets Failover partner Devices
----------------------------------------------------------------------------------------
sn11100n002 mgmt 4 / 4 sn11100n003 /dev/md0, /dev/md2, /dev/md4, /dev/
md6
sn11100n003 mgsmds 4 / 4 sn11100n002 /dev/md1, /dev/md3, /dev/md5, /dev/md7
sn11100n000 oss 0 / 0 sn11100n001
sn11100n001 oss 1 / 1 sn11100n000 /dev/md66
c. If both MGMT0 and MGMT1 started, and resources are correct, proceed to turn on the OSS nodes.
16. Change to root.
[admin@sn11100n000 ~]$
sudo su- root
Log in as
admin
. If a password is requested, use either
crayadm
or
masse2kd
.
17. Check to see which nodes are powered on:
[root@sn11100n000 ~]#
pm -q
on: sn11100n[000-003]
off:
unknown:
18. Power on the remaining nodes, as root:
[root@sn11100n000 ~]#
pm -1 desired node [00x-00x]
sn11100n[00x-00y]
IMPORTANT: For large systems, to avoid system power surge and network timeouts, limit selected
nodes to fewer than 50 nodes at one time.
19. Verify that the nodes are powered on:
[root@sn11100n000 ~]#
pm -q
on: sn11100n[000-003]
off:
unknown:
20. Verify that the resources have started:
[root@sn11100n000 ~]#
pdsh -a date | sort
The output shows all nodes in sequential order, and their status. This may take several minutes.
21. To continue system operation, verify that the system is in Daily mode:
[root@sn11100n000 ~]#
cscli cluster_mode --status
cluster_mode: Cluster is in 'Daily' mode.
cluster_mode: name: sn11100n
cluster_mode: UUID: 15fd9368-d665-11e5-9b44-0025901f832e
a. If the cluster is indicated to be in Daily mode as shown, power up is complete.
b. If the system is not in Daily mode, contact Cray hardware product support (HPS).
Power On the ClusterStor L300 and L300N System