85
Cranesmart LMI Version R9
Display Panel
– Alarms
The panel has built-in audible and visual alarms. The alarm screens alternate with the primary operating screen to notify
the operator of unsafe crane conditions while continuing to provide load and positional information. The alarms are
accompanied by an audible alarm provided within the panel. The example below is a Main A2B two-block alarm. To
further help in troubleshooting there is an alarm number in the lower right hand corner of the screen. This number
coincides with the alarm that is appearing on the screen. If the alarm is too fast to read the number can be used to
identify the alarm.
When the display panel is installed and powered you may see system error screens and hear alarms. The alarms may
indicate which component (load cell, anti-2-block, angle transducer, etc) signal is not being received.
The alarms are normal until all parts of the system are installed and there is a clear line of sight to the antenna. If all the
parts of the system are correctly installed and the alarms are still sounding, check your signal strength screen (see page
83) to see if your boom mounted transmitters are sending a clear signal. You may also try moving your cab mounted
antenna for better reception.
If neither of these solutions solves the problem call our service department at (888) 562-3222 or (780) 437-2986.
NOTE:
The audible alarm is intended for the operator to hear. If you require a louder horn that can be heard across a platform or jobsite,
Cranesmart™
Systems can provide a louder horn, which automatically increases in loudness depending on the ambient noise.
Summary of Contents for LMI System
Page 1: ...Cranesmart Systems LMI System User Manual May 11 2015 Rev 9...
Page 23: ...22 Cranesmart LMI Version R9...
Page 43: ...42 Cranesmart LMI Version R9 Basic Wiring Diagram...
Page 45: ...44 Cranesmart LMI Version R9 Junction Box Wiring Diagram...
Page 47: ...46 Cranesmart LMI Version R9 Alarm Hub Wiring Diagram...
Page 91: ...90 Cranesmart LMI Version R9 Technical Specifications 7 500lb single line pull load cell...
Page 92: ...91 Cranesmart LMI Version R9 15 000 single line pull load cell...
Page 93: ...92 Cranesmart LMI Version R9 25 000lb single line pull load cell...
Page 94: ...93 Cranesmart LMI Version R9 40 000lb single line pull load cell...
Page 95: ...94 Cranesmart LMI Version R9 50 000lb single line pull load cell...
Page 96: ...95 Cranesmart LMI Version R9 80 000lb single line pull load cell...
Page 97: ...96 Cranesmart LMI Version R9 Anti 2 Block Switch...
Page 98: ...97 Cranesmart LMI Version R9 Boom Angle Transducer...
Page 99: ...98 Cranesmart LMI Version R9 Display Panel...
Page 100: ...99 Cranesmart LMI Version R9 Alarm Hub...
Page 101: ...100 Cranesmart LMI Version R9 Wind Speed Transducer...