63
Cranesmart LMI Version R9
3. Use the Up or Down arrows, select Limits.
4. Use the Up or Down arrows, select Radius, you will be defaulted to the Max of the Main Radius.
5. Select Max.
6. Use the Up or Down arrows, set Maximum Radius.
7. Press Accept twice to save.
8. Use the Up or Down arrows, select Min.
9. Use the Up or Down arrows, set Minimum Radius.
10. Press Accept twice to save.
11. Repeat steps 4 to 10 for Aux 1 and Aux 2 Radius.
12. Select Exit to return to Primary Operating Screen, Select Back to return to the Limits menu or Select Top Menu to return to the Top Menu.
Level Transducer Limits
1. From the Primary Operating screen press select until the Secondary Operating screen is displayed.
2. Use the Up or Down arrows, to highlight Setup. Press select.
3. Use the Up or Down arrows, to highlight Limits. Press select.
4. Use the Up or Down arrows, to highlight Pitch-Roll. Press select.
5. You will be defaulted to Max Roll Angle. Press select.
6. Use the Up or Down arrows to adjust the Maximum limit for the Roll Angle.
7. Press Accept twice to save.
8. Use Up or Down arrows to highlight Max Pitch Angle. Press Select.
9. Use the Up or Down arrows to adjust the Maximum limit for the Pitch Angle.
10. Press Accept twice to save.
11. Highlight Exit and press select to return to Primary Operating Screen, Select Back to return to the Limits menu or Select Top Menu to return
to the Top Menu.
Wind Limits
1. From the Primary Operating screen press select; the Secondary Operating screen is displayed.
2. Use the Up or Down arrows, select SETUP.
3. Use the Up or Down arrows, select LIMITS.
4. Use the Up or Down arrows, select WIND.
Summary of Contents for LMI System
Page 1: ...Cranesmart Systems LMI System User Manual May 11 2015 Rev 9...
Page 23: ...22 Cranesmart LMI Version R9...
Page 43: ...42 Cranesmart LMI Version R9 Basic Wiring Diagram...
Page 45: ...44 Cranesmart LMI Version R9 Junction Box Wiring Diagram...
Page 47: ...46 Cranesmart LMI Version R9 Alarm Hub Wiring Diagram...
Page 91: ...90 Cranesmart LMI Version R9 Technical Specifications 7 500lb single line pull load cell...
Page 92: ...91 Cranesmart LMI Version R9 15 000 single line pull load cell...
Page 93: ...92 Cranesmart LMI Version R9 25 000lb single line pull load cell...
Page 94: ...93 Cranesmart LMI Version R9 40 000lb single line pull load cell...
Page 95: ...94 Cranesmart LMI Version R9 50 000lb single line pull load cell...
Page 96: ...95 Cranesmart LMI Version R9 80 000lb single line pull load cell...
Page 97: ...96 Cranesmart LMI Version R9 Anti 2 Block Switch...
Page 98: ...97 Cranesmart LMI Version R9 Boom Angle Transducer...
Page 99: ...98 Cranesmart LMI Version R9 Display Panel...
Page 100: ...99 Cranesmart LMI Version R9 Alarm Hub...
Page 101: ...100 Cranesmart LMI Version R9 Wind Speed Transducer...