17
Cranesmart LMI Version R9
Load Cell Battery Replacement
The display panel will indicate a low battery for approximately three (3) weeks before the battery fails.
Starting for systems sold during and after February 2008,
Cranesmart™ Systems will supply replacement power cells for
our transmitters for the cost of freight shipping (customers are responsible for any incurred taxes/duties).
Before replacing the batteries call the service department at (888) 562-3222 or (780) 437-2986. Once you have verified
that it is a dead battery follow the steps below.
Please have the serial number of your system handy before calling for replacement batteries or to ask for
technical assistance. You can find the serial number on either the display panel or the load cell itself.
Tools and Equipment for battery replacement:
Battery replacement kit contains:
One 3.6 volt Lithium Ion D-cell battery
Two O-rings
– (one for a 7.5/15/25K load cell, one for a 40K and larger load cell)
One 6g packet of Silicone Grease (Dow corning 111 or similar)
One 5/32” Allen key
The Kit also contains the following:
Two battery cover gaskets
– (one for a 7.5/15/25K load cell, one for a 40K and larger load cell)
One tube of RTV Silicone Sealant (Dow corning 734 or similar)
These parts are designed for use with the older gasket sealed load cells and
are not to be used
with o-ring sealed load cells.
NOTE:
SAFT 33600 3.6V Lithium power cells may also be available from local sources. Ensure that you take the existing battery with you if possible for
correct size matching.
Other manufacturer‟s may not follow the SAFT sizing conventions.
If you purchase your own battery you will also need to reuse the o-ring. Please ensure that you use grease, as per the instructions below, when
installing the o-ring.
Summary of Contents for LMI System
Page 1: ...Cranesmart Systems LMI System User Manual May 11 2015 Rev 9...
Page 23: ...22 Cranesmart LMI Version R9...
Page 43: ...42 Cranesmart LMI Version R9 Basic Wiring Diagram...
Page 45: ...44 Cranesmart LMI Version R9 Junction Box Wiring Diagram...
Page 47: ...46 Cranesmart LMI Version R9 Alarm Hub Wiring Diagram...
Page 91: ...90 Cranesmart LMI Version R9 Technical Specifications 7 500lb single line pull load cell...
Page 92: ...91 Cranesmart LMI Version R9 15 000 single line pull load cell...
Page 93: ...92 Cranesmart LMI Version R9 25 000lb single line pull load cell...
Page 94: ...93 Cranesmart LMI Version R9 40 000lb single line pull load cell...
Page 95: ...94 Cranesmart LMI Version R9 50 000lb single line pull load cell...
Page 96: ...95 Cranesmart LMI Version R9 80 000lb single line pull load cell...
Page 97: ...96 Cranesmart LMI Version R9 Anti 2 Block Switch...
Page 98: ...97 Cranesmart LMI Version R9 Boom Angle Transducer...
Page 99: ...98 Cranesmart LMI Version R9 Display Panel...
Page 100: ...99 Cranesmart LMI Version R9 Alarm Hub...
Page 101: ...100 Cranesmart LMI Version R9 Wind Speed Transducer...