34 of 104
bent, pinched, or twisted in such a
way as to prevent the flow of
condensate. Periodically inspect the
drain pan, drain tube, and drain hose
for alignment and the presence of
dirt, debris, mold, and mildew. Clean
as needed.
WARNING
THE COMPRESSOR ELECTRICAL CIRCUIT IS
ALWAYS LIVE WHEN THE PLUG IS CONNECTED
TO AN ELECTRICAL OUTLET.
REFRIGERATION CONDENSER
Clean the condenser periodically of dirt or lint
build-up. Remove the build up with a brush or
vacuum, or blow the dirt out of the condenser
with compressed air and approved safety nozzle.
Ensure nothing obstructs air intake at the bottom
of the main door. Ensure nothing obstructs air
exhaust at the rear of the cabinet.
COIN ACCEPTOR
Follow the Coin Acceptor Manufacturer’s
instructions.
LUBRICATING THE VENDER
The vender refrigeration system does not require
any field lubrication. The hermetic refrigeration
system and fan motors are manufactured with
lifetime lubrication.
NEW CONTROL BOARD INSTALLATION
Set Model Number. On power up the display will
show “Reset Model? Continue?
= Yes CLR = No”.
Pres the
key and display will show “No Model Set
Save? A = ^ (scroll up)
= Yes CLR = No”. Press
key A to scroll through available model numbers
DN5800-4, DN3800-4, DN5800-E4 (export),
DN3800-E4 (export). With vender model displayed
that you are installing board press the
key to save.
UPDATE SOFTWARE
The following information describes how to update
software. All new software revisions will
automatically update the software revision in the
control board.
Important
: Eproms containing
software are sensitive to Electrostatic Discharge
(ESD). Failure to handle the Eprom carefully could
cause damage, which may result in a failed control
board.
ALWAYS KEEP THE EPROM IN THE ESD
TUBE. GROUND YOURSELF ON THE VENDER
CABINET BEFORE REMOVING THE EPROM
FROM THE ESD TUBE OR CONTROL BOARD.
AN EPROM CAN BE USED TO PROGRAM MANY
VENDERS, AS LONG AS CARE IS TAKEN NOT
TO DAMAGE THE EPROMS LEGS.
ALWAYS
TURN POWER OFF BEFORE REMOVING OR
INSTALLING EPROMS IN THE CONTROL
BOARD.
EPROM Removal:
a. Power down the Vender. Ground
yourself on the vender cabinet
before removing the EPROM from
the ESD tube or control board.
b. If an Eprom is present in the control
board, remove the existing Eprom.
ii. Note; An Eprom does not
need to be in the control
board after the control board
has been programmed. The
Eprom can be used to
program other boards.
c. Verify the pins of the new Eprom are
not bent before installing in the
Eprom socket.
d. Install the new Eprom in the Eprom
socket. Ensure the Eprom is
oriented correctly with its reference
marker (locator) in the same
direction as the reference marker
(locator) of the Eprom socket. Do
not rely on the Eprom label for
orientating the Eprom.
4. Automatic
Reprogramming:
e. Turn power on to Vender. When
auto-updating the display will show
old version for a few seconds while
the red LED on the control board
blinks.
f. Display will change to “EPROM
UPGRADE…” for approximately 10
seconds with the green LED rapidly
blinking.
g. Display will change to new version
software with red LED blinking at a
steady heart beat rate.
Note: to remove the Eprom after programming,
remove power to the vender, ground yourself on the
vender cabinet before removing the Eprom, remove
the Eprom, while still grounded install a label on the
microprocessor showing the revision of software that
is installed in the controller, power the vender back
on and test for proper operation.
Summary of Contents for BevMAX 4 Series
Page 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Page 71: ...70 of 104 ...
Page 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Page 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Page 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Page 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Page 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Page 100: ...99 of 104 ...