![Crane Merchandising Systems BevMAX 4 Series Technical Manual Download Page 28](http://html.mh-extra.com/html/crane-merchandising-systems/bevmax-4-series/bevmax-4-series_technical-manual_2679246028.webp)
27 of 104
Dixie-Narco Factory Setup
Menus - BevMax Setup/Test
Modes/Satellite (137/937)
Setup
The below diagnostic features are used for aligning
the XY assembly and providing pertinent information
that is unique to the Coca-Cola BevMax 4 Vender
and is not found in the standard programming of the
vender. These include menus for “BevMax Setup”,
Test Modes”, and “Satellite (137/937) Setup”. The
menus include the following sub-menus. In BevMax
Setup you have “Set Price/Temperature 4 Test”, “Set
Price/Temperature Default”, “Set Shelf Offset”,
“Position Test”, “Set Hook Offset”, “Cup Sensor
On/Off”, “Cup Test”, “Port Test”, “Set Shelf
Configuration”, “Master Reset”, “Update Software”,
“Double Talk”, and “Build Number ###”. In Test
Modes you have “Test Vend”, “Test Sel Switch”,
“Test Display”, and “Test Relays”. In Satellite
(137/937) Setup you have “Enable Snack Vender”,
“Golden-Eye Policy”, Set Golden-Eye Sel”, Snack
Motor Scan”, and “Combo Vend Discount En”.
To enter “BevMax Setup” sub menus:
Press the service switch on the controller (Blue
button on the control board). When the display reads
"Error Codes" press and let go of the following keys
in order; "1" "5" "1" "5" "1". If the keys were actuated
correctly, the VMC will enter the factory diagnostic
mode and the display will read "BevMax Setup".
Press the number 2 key to scroll to Test Modes or
press the number "4" key one time will cause the
VMC to enter the BevMax Setup sub menu or press
and hold the number "1" key for 1 second to exit the
"BevMax Setup" submenu and return to the "Error
Codes" service menu prompt. Once you enter the
"BevMax Setup" mode press key 4 to enter submenu
and Coke Factory Setup Set Prc/Tmpr 4 Test will
show on display, press and hold the number "2" key
and the VMC will begin to cycle forward through the
available options or press and hold the number “3”
key to cycle backwards through the available
options. Press key 4 one time at any option for the
VMC to enter that option.
BevMax Setup
Coke Factory Setup
Set Model Number
Press key 4 to enter menu
Displays “Reset Model?
Continue 4 = Y, 1 = N
Press A key to scroll thru the models.
Models are 3800-4, 5800-4, 3800-E4, 5800-E4. The
display will display save? A =
^
,
= Y, Clear = no.
Press the
key at the correct model to save setting.
Note: Program the model 5800-4 for all Domestic
BevMax 4 & 3 Venders with 9 columns per shelf.
Program the model 3800-4 for all Domestic BevMax
3800-4 with 7 columns per shelf. There is not an
option for a model number for 5800 and 3800 glass
front.
Coke Factory Setup
Set Prc/Tmpr 4 Test – (DO NOT USE IN
THE FIELD)
This sub menu will be used to set the vend price and
temperature during our factory testing and should not
be used in the field.
Coke Factory Setup
Set Prc/Tmpr Default – (DO NOT USE IN
THE FIELD)
This sub menu will be used to set the vend price and
temperature back to factory default settings during
our factory testing and should not be used in the
field. Press key 4 and display will show “Set to
Default? Continue? 4=Y 1=N. Press key 4 to set
price and temperature settings to factory default
settings.
Coke Factory Setup
Set Shelf Offset
–
Test Delivery Cup to Shelf
Alignment
:
This sub menu will be used to set the XY to the
proper shelf height. Press key number "4" one time
at the “Shelf Offset” prompt. The VMC will enter the
shelf adjust option and display the current shelf offset
position as “Shelf Offset: 900 3310 counts = 1 inch”.
To adjust Shelf (Y) Offset (up and down), enter a
new number and press the “
” key to save and
display will show “#### Offset recorded. Then press
“CLR to go back to “Shelf Offset”. Go to Position
Test and check the plunger is contacting the targets
correctly.
Coke Factory Setup
Position Test
–
Test Delivery Cup to column
selected
:
This sub menu will be used to test the vend
mechanism alignment to specific columns confirming
the proper X belt tension. Note: The left door switch
must be pulled to the out position to perform this test.
Caution: XY needs to be in the home position
before performing this test.
If you look at the
control board the green, amber (yellow), and red
lights should be on at this time. If not please check
the following: Green light is for home switch on
bottom of port cup, amber (yellow) light is for home
Summary of Contents for BevMAX 4 Series
Page 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Page 71: ...70 of 104 ...
Page 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Page 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Page 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Page 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Page 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Page 100: ...99 of 104 ...