12 of 97
“Remote Vend Mech” - Remote Vend
Mechanism
(USD) Error.
Press key number 4 and the display shows one of the
following.
- “Remote Vend Comm #”, indicates no
communication for 5 seconds with remote vend
mech at address “#”.
- “Remote Vend #”, indicates error code number “#”
from the remote vend mech at address “a”.
Press key number 1 will return to “Remote Vend Mech”
if all remote vend mechanism Error Codes have not
been cleared. If all remote vend mechanism Error
Codes have been cleared the next error code will be
displayed, or “No Error Codes” if there are no Error
Codes. Press key number 1 will return to “Error
Codes”. Press key number 2 will scroll to the next
routine.
“SAT” – Satellite Device Error.
Press key number 4 and the display shows one of the
following.
- “SATC”, satellite communication issue.
- “BADM”, bad motor reported.
- “MISM”, missing motor reported.
Press key number 1 will return to “SAT” if all SAT Error
Codes have not been cleared. If all SAT Error Codes
have been cleared the next error code will be displayed,
or “No Error Codes” if there are no Error Codes. Press
key number 1 will return to “Error Codes”. Press key
number 2 will scroll to the next routine.
“Select/Display” - Selection / Display
Device (ASD) Error
Press key number 4 and the display shows:
-
“Select/Display Comm”, indicating no
communication to selection / display device for
five seconds.
Press key number 1 will return to “Select/Display” if all
selection / display device Error Codes have not been
cleared. If all selection / display device error have been
cleared the next error code will be displayed or “No
Error Codes” if there are no Error Codes.
Press key number 1 will return to “Error Codes”.
Press key number 2 will scroll to the next routine.
“Refrigeration” - Refrigeration Summary
Error Codes
Press key number 4 and the display shows one of the
following:
- “Temp Sense Err”, indicating the temperature
sensor is defective or unplugged.
- “Temp Too Cold”, indicating the cabinet
temperature is 3
0
F below lower limit.
- “Temp Too Hot”, indicating the cabinet
temperature is 3
0
F above upper limit.
- “Not Cooling”, indicating the cooling system has
failed to decrease temperature 1
0
F per
hour while the compressor is running.
- “Health Timer” – Health Timer Error
The initial pull down time has not met the
health timer constraints. Refer to “Health
Timer” section for details. Press and hold
key number 4 for 2 seconds will clear the
error and the display will show “No Error
Codes”.
- “Health Code” – Health Code Error
The health code cooling constraints have
not been met. Refer to “Health Timer”
section for details. Press and hold key
number 4 for 2 seconds will clear the error
and the display will show “No Error
Codes”.
Press key number 1 will return to “Refrigeration” if all
refrigeration summary errors have not been cleared. If
all refrigeration summary Error Codes have been
cleared the next error code will be displayed, or “No
Error Codes” if there are no Error Codes. Press key
number 1 will return to “Error Codes”. Press key
number 2 will scroll to the next routine.
“Coin Pay Out” - COIN PAYOUT ROUTINE
This function allows you to dump coins from the coin
mechanism. Note: If a coin mech is not installed, you
will not be able to enter the program to display
information. Press key number 4 to enter mode and the
lowest coin value dispensable will show on the display.
Press key number 2 or 3 to scroll through the different
coin values available. Press and hold key number 4 to
dump the coins whose value is shown on the display.
Press key number 1 will return to “Coin Pay Out”. Press
key number 2 to scroll to the next routine.
“Tube Fill” - TUBE FILL ROUTINE
This function allows you to count the coins loaded in the
top (separator) of the coin mech that will be routed to an
inventory tube. Note: If a coin mech is not installed,
you will not be able to enter the program to display
information. Press key number 4 to enter mode and the
total number of the coin type being loaded will be
displayed and counted in the vender controller as they
are accepted. The controller will inhibit the acceptance
of any coin which does not go to a tube during this
procedure. If a tube full status is detected, that coin type
will be inhibited. When you finish loading all coins press
key number 1 to return to “Tube Fill”. Press key number
2 to scroll to the next routine.
“Test Modes” - TEST ROUTINE
This function allows you to diagnose different functions
of the vender. Press key number 4 and the display will
show “Test vend”. For additional Dixie-Narco Factory
Diagnostics refer to page 27. Press key number 2 or 3
Summary of Contents for BevMAX 4 Series
Page 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Page 71: ...70 of 104 ...
Page 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Page 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Page 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Page 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Page 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Page 100: ...99 of 104 ...