11 of 97
Mechanism” if all vend mech Error Codes have
not been cleared. If all vend mech Error Codes
have been cleared the next error mode will be
displayed, or “No Error Codes” if there are no
Error Codes. Press key number 1 will return to
“Error Codes”.
“Control System” - Control System
Summary Error Codes
Press key number 4 and the display will show one of
the following:
- “Door Switch”, indicating a door switch in the
open position for more than 1 hour.
- “RAM Checksum”, indicating the check sum for
service mode settings memory has been
corrupted.
- “Scale Factor”, indicating a peripheral has
introduced a scaling factor that is
incompatible with current setting.
“FRAM”, memory module read/write error.
- “RTC”, RTC read/write error, real time clock
issue.
- ‘Low Battery”, low battery issue.
- “PWROUT”, power lost.
Press key number 1 will return to “Control System” if all
control system Error Codes have not been cleared. If
all control system Error Codes have been cleared the
next error code will be displayed, or “No Error Codes” if
there are no Error Codes. Press key number 1 will
return to “Error Codes”.
“CHANGER” - Changer Summary Error
Codes
Press key number 4 and the display will show one of
the following:
- “Changer Comm”, indicating a changer
communication error (No communication for
more than 2 seconds).
- “Tube Sense”, indicating a tube sensor error.
- “Changer Inlet”, indicating an inlet chute blocked
error (no coins sensed in acceptor for 96 hours).
- “Tube Jam #”, indicating a tube jam error.
- “Changer ROM”, indicating a changer ROM
check sum error (failed changer).
- “Excessive Escrow”, indicating excessive escrow
attempts (more than 255 since last coin sensed).
- “Coin Jam”, indicating a coin jam reported by coin
mech.
- “Low Acceptance”, indicating a low coin
acceptance rate (less than 80%).
- “Acceptor Disconnected”, indicating an acceptor
is unplugged.
- “Coin Routing Err”, indicating a coin was miss-
routed.
Press key number 1 will return to “CHANGER” if all
changer Error Codes have not been cleared.
If all changer Error Codes have been cleared the
next error code will be displayed or “No Error
Codes” if there are no Error Codes. Press key
number 1 will return to “Error Codes”.
“Bill Validator” - Bill Validator Summary
Error Codes
Press key number 4 and the display will show one of
the following:
- “Bill Val Comm” indicating a bill validator
communication error (No communication for more
than 5 seconds).
- “Bill Stack Full” indicating the bill stacker is full.
- “Bill Motor Error” indicating a defective motor in
the validator.
- “Bill Jam ” indicating a bill jam in the validator.
- “Bill Val ROM” indicating a check sum error.
- “Bill Stack Open” indicating an open stacker.
- “Bill Sense Err” indicating a bill validator sensor
error.
Press key number 1 will return to “Bill Validator” if all
changer Error Codes have not been cleared.
If all validator Error Codes have been cleared the
next error code will be displayed or “No Error
Codes” if there are no Error Codes.
Press key number 1 will return to “Error Codes”.
“Card Reader” - Card Reader Summary
Error Codes
Press key number 4 and the display will show one of
the following:
- “Card Reader Comm”, indicating no card reader
communication for 5 seconds.
- “Card Reader #”, indicating the most recent “non-
transient error” from the card reader (failed card
reader).
Press key number 1 will return to “Card Reader” if all
changer Error have not been cleared. If all card reader
Error Codes have been cleared the next error code will
be displayed or “No Error Codes” if there are no Error
Codes. Press key number 1 will return to “Error
Codes”. Press key number 2 will scroll to the next
routine.
“OLM” – On Line Module Summary Error
Codes
Press key number 4 and the display will show one of
the following:
- “On Line Network”, error reported by the OLM.
- “On Line Internal”,
error reported by the OLM.
Press key number 1 will return to “OLM” if all OLM
Errors have not been cleared. If all OLM Error Codes
have been cleared the next error code will be displayed
or “No Error Codes” if there are no Error Codes. Press
key number 1 will return to “Error Codes”. Press key
number 2 will scroll to the next routine.
Summary of Contents for BevMAX 4 Series
Page 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Page 71: ...70 of 104 ...
Page 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Page 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Page 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Page 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Page 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Page 100: ...99 of 104 ...