19 of 97
you wish to use. Display will return to
“XXXXXX#”. Press key number 2 to scroll to
the next day to set or press key number 1 to
return to “Start Day”. Press key number 2 to
scroll to “Start Hour”.
“Start Hour”
- Start Hour and Minute Setting
This function is used to set the hours to start
light conservation (lamps off). Press key
number 4 and “hhmm” will show on the display,
where “hh” is the hour (military time) and “mm”
is the minute. “hh” will be blinking, indicating
the hour setting may be changed. Press key
number 2 to scroll from 00 to 23. With the
display showing the hour you wish to start light
conservation, press key number 4. “mm” will
start blinking, indicating the minute setting may
be changed. Press key number 2 to scroll from
00 to 59. With the display showing the minute
you wish to start light conservation, press key
number 4. The display will return to “Start
Hour”. Press key number 1 to return to “Start
Time”. Press key number 2 to scroll to “Stop
Time”.
“Stop Time”
- Stop Light Conservation Setting
(lights on)
This function is used to set the days and time to
stop light conservation. Press key number 4 and
“Stop Day” will show on the display.
“Stop Day”
- Day to Stop Setting
This function is used to set the days of the
week to stop light conservation and can be set
in the same manner as Day to Start Setting.
“Stop Hour”
- Stop Hour and Minute Setting
This function is used to set the hours and
minutes to stop light conservation and can be
set in the same manner as Start Hour and
Minute Setting. Press key number 1 to return to
“Stop Time”. Press key number 1 to return to
“Lighting Control”. Press key number 2 to scroll
to next routine.
*”Refrigeration ” - REFRIGERATION
ROUTINE
This function is used to electronically control the
refrigeration operations of the vender. Press key
number 4 will enter “Enable #”.
“Enable #”
- Energy Conservation Enable Routine
This function is used to disable Energy
Conservation “Enable 0” or enable Energy
Conservation “Enable 1”. When enabled the
cabinet temperature will be allowed to rise to the
programmed storage level (“Storage”) during the
following programmed time blocks. Press key
number 4 and the current “Enable X” setting will be
displayed. Press key number 2 or 3 to scroll
between “Enable 0” and “Enable 1”. Press key
number 4 with the display showing the setting you
wish to use. Press key number 2 to scroll to
“Start”.
“Start Time”
- Start Energy Conservation
This function is used to set the days and time to
start Energy Conservation when “Enable 1” is
selected. Press key number 4 and “Start Day” will
show on the display.
“Start Day”
- Day to Start Setting
This function is used to set the days of the
week to start Energy Conservation.
Press key number 4 and “XXXXXX#: will
show on the display, where XXXXXX will be
the day of the week (i.e. Monday, Tuesday,
Wednesday, Thursday, Friday, Saturday,
Sunday, Every day) and # is 0 = disable, 1 =
enable. With the display showing the day you
wish to set press key number 4. The # will
start blinking. Press key number 2 or 3 to
scroll between “XXXXXX0” and “XXXXXX1”.
Press key number 4 with the display showing
the setting you wish to use. Display will return
to “XXXXXX#”. Press key number 2 to scroll
to the next day to set or press key number 1
to return to “Start Day”. Press key number 2
to scroll to “Start Hour”.
“Start Hour”
- Start Hour and Minute Setting
This function is used to set the hours to
start Energy Conservation.
Press key
number 4 and “hhmm” will show on the
display, where “hh” is the hour (military time)
and “mm” is the minute. “hh” will be you wish
to start Energy Conservation, press key
number 4. The display will return to “Start
Hour”. Press key number 1 to return to “Start
Time”. Press key number 2 to scroll to “Stop
Time”.
“Stop Time”
- Stop Energy Conservation
This function is used to set the days and time to
stop energy conservation when “Enable 1” is
selected. Press key number 4 and “Stop Day” will
show on the display.
“Stop Day”
- Day to Stop Setting
This function is used to set the days of the
week to stop energy conservation and can be
set in the same manner as “Start Day” and
“Start Hour”.
“Start Hour”
- Stop Hour and Minute Settings
This function is used to set the hours and
minutes to stop energy conservation and can
be set in the same manner as “Start Hour”.
Press key number 1 to return to “Stop Time”.
Press key number 2 to scroll to “Degrees”.
“Degrees F(C)”
- Degree Fahrenheit / Celsius
Setting Routine
This function is used to set the degree reading
to Fahrenheit (Degrees F) or Celsius (Degrees
C). Press key number 4 and “Degrees X”,
where the current setting (X) will be blinking.
Summary of Contents for BevMAX 4 Series
Page 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Page 71: ...70 of 104 ...
Page 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Page 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Page 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Page 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Page 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Page 100: ...99 of 104 ...