Do a Keypad
test.
Go to DN Factory
Diagnostics BevMax Setup
Coke Factory Setup Set Shelf
Offset. Check encoder
counts. Send to home, does
home switch light come on?
YES
NO
Check Harness,
Motor, Board.
See XY not
working
page 34
Send cup to “A9”
position. Press “4”
to go home. Did
green light flicker?
YES
NO
Check, repair,
or replace X
Axis E-chain
Ground wire.
Send cup to “A”
shelf. Is cup in
correct location?
YES
NO
Fire the plunger to ensure
correct location. Repeat
“A-E” cycle two to three
times. Is cup in correct
location?
YES
NO
Repeat “A-E” cycle two to
three times. Does cup
position get worse?
YES
NO
Go to DN Factory
Diagnostics BevMax Setup
Coke Factory Setup Set
Shelf Offset and check.
Adjust as necessary. See
DN Factory Diagnostics
section of manual.
CUP AT WRONG LOCATION
HIGH/LOW or Y AXIS
Close door
and test vend.
Is shelf setting correct?
YES
NO