67 of 104
BevMax 4 5800-4/3800-4 AC Distribution Box
Domestic Test Voltages 9 Pin J2 Output Power Connector
1
st
lead to Pin
2
nd
lead to
Domestic Reading
1
2
24 (26 to 30) VAC secondary of transformer
2
1
24 (26 to 30) VAC secondary of transformer
3
ground
110 VAC Hot not switched for 1 lamp assy.
4 NA
OPEN
5
ground
115 VAC Hot switched for fan motor
6
ground
115 VAC Hot switched for lights
7
ground
0 VAC Neutral
8
ground
0 VAC Neutral
9
ground
0 VAC Neutral
Domestic Test Measurements 4 Pin P7 AC Distribution Box
1
st
lead to Pin
2
nd
lead to Pin
Domestic Reading
When 4 pin connector is
unplugged – OHMS reading
1
3
Lights control relay coil
570 ohms
2
3
Fan control relay coil
570 ohms
4
3
Compressor relay coil
570 ohms
3 NA
Common
NA
1
9
3
Domestic
AC Box
Shown
J2
J2
P7
1
2
4
Defrost Control
Connector
1 3
9
1
4
2
Summary of Contents for BevMAX 4 Series
Page 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Page 71: ...70 of 104 ...
Page 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Page 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Page 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Page 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Page 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Page 100: ...99 of 104 ...