32 of 104
current state of “Golden-Eye Policy Drop” or
“Golden-Eye Policy Home”. Home = motor will
always return to the home position after a product
drop failure and Drop = motor will rotate one
complete revolution, pause, then stop upon
detection of product falling into bin (may leave the
spiral in mid cycle). Important: If you use Drop
feature, before filling the Satellite (137/937)
machine you should press the service mode switch
on the control board and then press the door
interlock switch on the Satellite (137/937) to force a
scan of the snack motors and return them to the
normal home position. Failure to do this may result
in Full Selections Being Left Out Of Order or spirals
dropping products after the machine has been filled.
Press key number 2 or 3 to scroll between “Golden-
Eye Policy Drop” or “Golden-Eye Policy Home”.
Press key number 4 with the display showing the
setting you wish to use. Display will return to “Golden-
Eye Policy”.
Press key number 2 to scroll to next menu item.
Satellite (137/937) Setup
Set Golden-Eye Sel
–
Golden-Eye operating
condition
:
This sub menu is used to set up the Golden-Eye
Selections. Press key number 4 and display will
show “Set Golden-Eye Sel Sel: ### 1(0)” where ###
is the column number and the 1 = enabled or 0 =
disabled. Press key 4 and the 1(0) will start flashing,
press key 2 to toggle between 1 and 0. With the
display showing the condition you wish to use press
key 4 to save. Display will show column & setting
selected. Press key 2 to scroll to next column and
repeat for all columns as needed. Press key 1 to
return to “Set Golden-Eye Sel “. Press key number 2
to scroll to next menu item.
Satellite (137/937) Setup
Snack MotorScan
–
Verify State o
f
Satellite
(137/937) Motors
:
This sub menu is used to verify the state of the
selection motors in the Satellite (137/937) Vender.
Press key number 4 and display will show “Snack
Motor Scan Execute Motor Scan?”. Press key
number 4 and the display will show the results of the
last motor scan test. Press key 2 to scroll through
the results. Press key 4 to initiate a new scan of the
motors. The display will say Scanning Motors.
When scan is complete the display will say Scanning
motors done press * to continue. Press key 2 to
scroll through the results. The report will show Motor
Scan Results Good Motors:## (number of good
motors detected), Motor Scan Results Bad
Motors:## (number of bad motors detected), and
Motor Scan Results Missing Motors:## (number of
missing motors detected). Note: If a selection motor
runs 3 times without delivering a product the
selection is then locked out until a motor scan or
door open close occurs. Press key number 1 to
return to “Snack Motor Scan”. Press key number 2 to
scroll to next menu item.
Satellite (137/937) Setup
Combo Vend Discnt En
–
Enable the Combo
Vend Discount that has been set
:
This sub menu is used to enable and disable the
Combo Vend Discount when a Snack Vender is
attached to the BevMax 4. 0 = off, 1 = on. Press key
number 4 and “#” will start flashing. Press key number
2 or 3 to scroll between “Combo Vend Discount Enable
0” and “Combo Vend Discount Enable 1”. Press key
number 4 with the display blinking the setting you wish
to use.
Important
: The Multivend option in BevMax
programming must be enabled for Combo Vend
Discount to function. Display will return to “Combo
Vend Discount En”.
Press key number 1 to return to “BevMax Setup”.
Major Component Description
AC DISTRIBUTION BOX
BevMax 4 5800-4/3800-4
110 VAC units
Main Power Switch / Plug
Interrupts hot side of
incoming power to
all components in
machine.
15 Amp Outlet (110 VAC)
Provides power to
Refrigeration
unit.
Transformer
(T1)
Provides 24 Volt
power to the
Controller Board.
DN5800-E4/3800-E4
220 VAC units
Main Power Switch / Plug
Interrupts hot side of
incoming power to
all components in
machine.
Receptacle, Panel Mount
Provides power to
IEC 320 (220 VAC)
Refrigeration unit.
Transformer
(T1)
Provides 24 Volt
power to the
Controller Board.
Service Door Switches
If 2 Switches - Left Switch
(10 Amp) – in XY Motor
Circuits, Port Door Motor Circuit, and Picker Motor
Circuit (Power Interrupt Switch).
If 2 Switches - Right Switch
(.1 Amp) – in
Controller Circuit.
Summary of Contents for BevMAX 4 Series
Page 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Page 71: ...70 of 104 ...
Page 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Page 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Page 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Page 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Page 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Page 100: ...99 of 104 ...