REF C04717-02-91 Q-NRG User Manual, Edition 4.2
Chapter 3 - Q-NRG Operation
COSMED srl
To download test results to OMNIA software, refer to”Download tests to OMNIA”.
Example of PDF printout is shown below (the shadow highlighted area represents the averaged data):
COSMED
Rome - ITALY
www.cosmed.com
Test date
Test date
10/12/2018
10/12/2018
Time
Time
14:50
14:50
Subject
Canopy demo Canopy demo
Canopy demo Canopy demo
ID
123
123
Gender
Female
Female
Age
34
34
D.O.B.
02/26/1985
02/26/1985
Weight
58.0 Kg
58.0 Kg
Height
163.0 cm
163.0 cm
BMI (kg/m2)
21.8
21.8
Predicted Set
Harris/Benedict
Harris/Benedict
Test Position
Undefined
Undefined
Agitation
N/A
N/A
Sedation
N/A
N/A
Body Temp (°C)
0
0
Resting period
N/A
N/A
Fasting period
N/A
N/A
UN (g/day)
0
0
Indirect Calorimetry Report - Canopy Test
Indirect Calorimetry Report - Canopy Test
00:00
02:00
04:00
06:00
08:00
time
0
200
400
600
0
200
400
600
VO2 (mL/min)
VCO2 (mL/min)
00:00
02:00
04:00
06:00
08:00
time
0.0
0.4
0.8
1.2
0
1000
2000
3000
RQ (-)
EE (KCal/day)
Operator Notes
REE
1575
Kcal/day
116 %pred
VO2
225
mL/min
VCO2
198
mL/min
Substrates
FAT
41
(%)
CHO
59
(%)
PRO
0
(%)
Variability
VO2
2
%
VCO2
4
%
RQ
0.88
--
npRQ: --
Vp
27.1
L/min
FeCO2
1.00
%
FeO2
19.88
%
AVG Interval
05:00
min
Duration
00:10:00
min
Operator:
Operator:
Login: Administrator
Login: Administrator
Page 1 / 2
Page 1 / 2
Q-NRG+ SN: 2018060015
Q-NRG+ SN: 2018060015
Canopy demo Canopy demo [ 02/26/1985 - Female ]
Canopy demo Canopy demo [ 02/26/1985 - Female ]
Canopy Test: 10/12/2018 14:50
Canopy Test: 10/12/2018 14:50
Time VP VO2 VCO2 RQ EE FeO2 FeCO2 FiO2 FiCO2 Battery Marker Info
hh:mm:ss L/min mL/min mL/min - KCal/day % % % % % -
00:00:30 27.2 264 241 0.91 1864 19.70 1.19 20.87 0.10 59 0
00:01:00 27.1 259 234 0.90 1825 19.72 1.16 20.87 0.10 60 0
00:01:30 27.1 262 254 0.97 1873 19.69 1.25 20.87 0.10 60 0
00:02:00 26.9 241 252 1.05 1752 19.76 1.25 20.87 0.10 60 0
00:02:30 26.9 222 239 1.08 1625 19.84 1.19 20.87 0.10 60 0
00:03:00 26.8 214 214 1.00 1540 19.89 1.08 20.87 0.10 61 0
00:03:30 26.9 215 215 1.00 1548 19.89 1.08 20.87 0.10 61 0
00:04:00 27.2 239 219 0.92 1689 19.81 1.09 20.87 0.10 61 0 C
00:04:30 27.2 225 188 0.84 1561 19.89 0.95 20.87 0.10 61 0 A
00:05:00 27.1 233 196 0.84 1618 19.85 0.99 20.87 0.10 62 0 A
00:05:30 27.2 230 191 0.83 1594 19.87 0.96 20.87 0.10 62 0 A
00:06:00 27.1 230 199 0.87 1606 19.86 1.00 20.87 0.10 62 0 A
00:06:30 27.2 216 188 0.87 1510 19.92 0.95 20.87 0.10 63 0 A
00:07:00 27.1 218 201 0.92 1542 19.90 1.01 20.87 0.10 63 0 A
00:07:30 27.1 218 201 0.92 1542 19.90 1.01 20.87 0.10 63 0 A
00:08:00 27.1 224 209 0.93 1589 19.87 1.05 20.87 0.10 63 0 A
00:08:30 27.1 224 209 0.93 1589 19.87 1.05 20.87 0.10 64 0 A
00:09:00 27.2 227 201 0.89 1593 19.87 1.01 20.87 0.10 64 0 AC
00:09:30 27.0 227 194 0.85 1582 19.87 0.98 20.87 0.10 64 0 A
00:10:00 27.0 234 198 0.85 1627 19.84 1.00 20.87 0.10 64 0
Login: Administrator
Login: Administrator
Page 2 / 2
Page 2 / 2
Q-NRG+ SN: 2018060015
Q-NRG+ SN: 2018060015
Summary of Contents for Q-NRG
Page 1: ...Q NRG User Manual...
Page 2: ......
Page 32: ...30 148 REF C04717 02 91 Q NRG User Manual Edition 4 2 COSMED srl...
Page 40: ...38 148 REF C04717 02 91 Q NRG User Manual Edition 4 2 COSMED srl...
Page 86: ...84 148 REF C04717 02 91 Q NRG User Manual Edition 4 2 COSMED srl...
Page 121: ...119 148 REF C04717 02 91 Q NRG User Manual Edition 4 2 Appendix COSMED srl Appendix...
Page 148: ...146 148 REF C04717 02 91 Q NRG User Manual Edition 4 2 Appendix COSMED srl Notes...
Page 149: ...147 148 REF C04717 02 91 Q NRG User Manual Edition 4 2 Appendix COSMED srl...
Page 150: ...148 148 REF C04717 02 91 Q NRG User Manual Edition 4 2 Appendix COSMED srl...
Page 151: ......