Viper Service Manual
Publication Number: 621260373SER
- 26 -
© 2008-2012, IMI Cornelius Inc.
Error Log Menu
The Error Log screen displays information about any errors generated by the unit,
as shown in Figure 18. If no errors have been detected, the right side of the
display is blank. To view more than one error, press the Up or Down arrows on the
right side of the display to scroll through the error log. Button functions are
described in Table 8.
Figure 18. Error Log Screen
CO
2
OUT
System
CO
2
pressure is below required operating
pressure. This error occurs when the CO
2
sensor reports no or low CO
2
pressure for
more than one second. Error is cleared 10
sec. after restoral.
SYRUP OUT
Barrel
Syrup pressure is below required operating
pressure. This error occurs when the syrup
sensor reports no or low syrup pressure for
more than one second. Error is cleared 10
sec. after restoral.
CLOCK
System
The real time system clock is not functioning.
MTR CTL
EEPROM
System
Motor control EEPROM is bad or missing.
Table 7
Button
Description
BACK
Returns the display to the Select menu
RESET
Allows the user to reset the highlighted error (This button only
appears on certain manually resettable errors.)
Table 6
Displayed
Message
Action
Type
Description
Table 8
Button
Description
BACK
Returns the display to the Select menu
ERROR
LOG
12:51P
MAR
04
ERROR
NUMBER
2
#3
COMM
FAIL
BACK
OCCUR:
2:44
PM
3/04/08
CLEAR:
2:52
PM
3/04/08