PREVENTATIVE MAINTENANCE
S
UMMARY
There are no daily maintenance procedures required on the Viper unit other than
normal cleanup of spills or overspray and emptying the drip tray. Normal equip-
ment maintenance intervals are listed in Table 33.. It is recommended that a pre-
ventative maintenance procedure be performed every six (6) months. This
procedure should include all of the maintenance items described in Table 33.
and the following sections.
CAUTION
— Only trained and certified electrical, plumbing and
refrigeration technicians should service this unit. ALL WIRING AND
PLUMBING MUST CONFORM TO NATIONAL AND LOCAL
CODES.
Table 33.
Preventative Maintenance Summary
Maintenance Procedure
Frequency of Maintenance
Clean Air Filter
Monthly or more often, as necessary (See
Table 34.)
Check BRIX
Every six months or when changing syrup
types (See “BRIX Setup Menu” on page 40.)
Seal Change
Every six months
Clean Condenser Coil
Every six months or as necessary
Sanitize Unit
Every six months or when changing syrup
types
Check Water Filter
Every six months or if water pressure in the
system is low.
Change or Rotate Scraper Blades
Every six months
Check for Leaks
Every six months
Clean BIB Connectors & check opera-
tion of syrup sold out switches
Every six months or when changing syrup
types.
Check Clock Setting
Every six months or when changing to or
from daylight savings time
Change caged o-ring on models w/
Motorman Valves.
Every six months or when changing syrup
types.