Flushing the System
Flush the wash water from the system by performing the procedure in Table 41..
CAUTION — Flush the system thoroughly, residual sanitizing solution
left in the system may create a health hazard.
7.
Fill the barrel with sanitizing solution by opening the faceplate relief valve until
sanitizing solution comes out of the relief port.
8.
Hold a 16 oz. cup under the dispense valve. Hold the dispense valve fully
open until the cup is full.
9.
Use the brush provided with the unit to clean the relief port and clean the out-
let of the dispense valve with sanitizing solution.
10.
From the
Barrel Statu
s menu, press the
SPIN
button while highlighting the
appropriate barrel. This starts the scraper blade. Allow blade to operate for
minimum of 10, but no more than 15 minutes. Turn the scrapper blade off by
pressing the
OFF
button.
11.
Place a large container under the dispense valve and drain as much sanitizing
solution as possible from the barrel.
12.
When the pressure in the barrel drops, from the
Barrel Maintenanc
e menu,
press the
PURGE
button to re-pressurize the barrel with CO
2
. As sanitizing
solution level lowers in the barrel, partially close the valve to avoid spurting.
Table 40.
Step
Action
Table 41.
Step
Action
1.
Turn the Product/BRIX valve to the Product position.
2.
Manually open the manual water flow valve to start filling the barrel with wash
water. At the same time, open the faceplate relief valve until water comes out.
3.
From the Barrel Status menu, press the SPIN button while highlighting the
appropriate barrel. This starts the scraper blade. Allow the blade to operate for
fifteen seconds, then turn barrel OFF by pressing the OFF button.
4.
To drain the water from the system, turn the barrel OFF.
5.
Place a container under the barrel dispensing valve. Open the dispensing
valve and dispense all rinse water from the barrel. When the pressure in the
barrel drops, from the Barrel Maintenance menu, press the PURGE button to
re-pressurize the barrel with CO
2
. As the wash water level lowers in the barrel,
partially close the valve to avoid spurting.
6.
Remove the sanitizing fitting (p/n cc 28688) from the BIB connector and con-
nect a BIB containing syrup to the syrup line.
7.
Rotate the Product/BRIX valve to the BRIX position and open the valve at the
end of the tube.
8.
Hold a waste container under the BRIX tube to collect the sanitizing solution
from the syrup line and open the manual syrup flow valve to start filling the
syrup line with syrup. Continue to hold open the syrup flow valve until syrup
starts coming out of the BRIX tube.
9.
Perform a BRIX setup. See “BRIX Setup Menu” on page 40.
10.
Fill the barrel with product as described in Table 21.
11.
Perform motor calibration. See “Calibrating a Motor” on page 44.