Viper Service Manual
Publication Number: 621260373SER
- 66 -
© 2008-2012, IMI Cornelius Inc.
CO
2
S
HUTOFF
S
OLENOID
R
EPLACEMENT
The CO
2
shutoff valves and solenoids, shown in Figure 46, are located near the
center of the unit and are mounted on a bracket to the bottom of the chassis.
They control the injection of CO
2
with the syrup/water combination to provide the
final mixture for the product. There are one of these solenoids for each barrel in
the system. When working in this area, care should be taken not to damage or
misalign the CO
2
metering orfice. To replace one of these solenoids, perform the
procedure in Table 49..
Figure 46. Side View of CO
2
Shutoff Solenoid (2 Barrel Unit)
Table 48.
Step
Action
1
Disconnect power from the unit.
2
Remove the rear cover and the side panels.
3
Disconnect the CO
2
supply from the unit.
4
Remove and drain the water supply from the unit.
5
Disconnect the quick disconnect input and output water lines from the bottom
of the pump.
6
Disconnect quick disconnect CO
2
input from the bottom of the pump.
7
Remove the four (4) screws and locknuts holding the pump to the mounting
bracket.
8
Replace the pump.
9
Reverse the procedure to install the new pump.
CO
2
Metering
Orfice
CO
2
Shutoff
Solenoid
CO
2
Shutoff
Valve