Viper Service Manual
© 2008-2012, IMI Cornelius Inc.
- 39 -
Publication Number: 621260373SER
To move between one set of barrel parameters to the next, press the Right or Left
arrow keys. This moves the highlight to the first entry of the second barrel, etc.
Totals Menu
The Totals menu (Figure 28) shows the cumulative run time of the system, a
component of the system or an error. Some individual items may be reset, where
available, by highlighting the item and pressing the RESET button. The RESET
button is only displayed for items that may be reset, such as hours since the motor
seal was changed or the number of compressor cycles. Pressing the BACK button
returns to the Choose menu and saves the changes. The description of each item
in the Totals list is shown in Table 25.
To move between one set of barrel parameters and the next, press the Right or
Left arrow keys. This highlights the first entry of the second barrel, etc.
Figure 28. Totals Screen
LLS VALVE #1
This selection opens and closes the Liquid Line solenoid
and valve for barrel 1
BRL MOTOR #1
This selection turns the barrel 1 motor on and off
Table 24
Display
Description
Table 25
Display
Value
Description
POWER ON
HHHHH:MM
Shows how long the machine has been
powered up
SLEEP
HHHHH:MM
Shows how long the machine has been in
sleep mode
SYSTEM ERROR
HHHHH:MM
Shows how long the machine has had a sys-
tem error
COMP RUN #1
HHHHH:MM
Shows how long the compressor has been
running since the last reset
COMP CYCLES #1
########
Shows the number of compressor cycles
since the last reset
BARREL REFG #1
HHHHH:MM
Shows how long the barrel has been in
refrigeration mode
MOTOR ON #1
HHHHH:MM
Shows how long the motor has been run-
ning on a specific barrel
TOTALS
12:51P
MAR
04
POWER
ON
00079:34
SLEEP
00034:21
BACK
SYSTEM
ERROR
00003:45
COMP
RUN
#1
00006:53
COMP
CYCLES
#1
0000012
BARREL
REFG
#1
00006:54