Figure 34. System Screen
Security
System security is located on the System menu. It allows a supervisor or service
technician to keep unauthorized personnel from accessing the Maintenance
menu. This feature is activated on the System menu. When security is turned on,
users can only access the Main and Setup menus. The word LOCKED appears in
the upper left corner of the display to inform users that security is enabled.
Pressing the extreme Left and Right buttons (Buttons 1 and 5) on the bottom of
the display simultaneously and holding them for approximately five (5) seconds
unlocks the Security menu. If security is left ON on the System menu, when the
system times out or when the user goes back to the Main menu, security is re-
activated and the Maintenance menu is not accessable. To disable security,
access the System menu, highlight Security and press the OFF button.
Table 31
Display
Description
# OF BARRELS
This selection shows the number of barrels in the system
and allows the user to change the quantity.
# OF COMPRESSORS
This selection shows the number of compressors in the
sytem. Currently this number is fixed at one and cannot be
changed.
SECURITY
This selection allows the user to turn security on or off.
CMP #X SENSORS
This selection allows the user to choose which pressure
sensors are read for the compressor.
Table 32
Option
Button 2
Button 3
Button 4
Button 5
# of Barrels
-
+
# of Compressors
-
+
Security
OFF
ON
Compressor Sensors
NONE
LOW
HIGH
BOTH
SYSTEM
12:51P
MAR
04
#
OF
BARRELS
2
#
OF
COMPRESSOR
1
BACK
- +
SECURITY
OFF
CMP
#1
SENSORS
BOTH
CMP
#X
SENSORS
LOW
Introduction
A refrigeration system and an intelligent hot gas d