Viper Service Manual
© 2008-2012, IMI Cornelius Inc.
- 41 -
Publication Number: 621260373SER
Figure 29. BRIX Setup Screen
Figure 30. Splash Panel Mounting Screws
11
Measure BRIX
Place adequate amount of the product on a
refractometer and read the BRIX value. A target
BRIX reading of 13.0 (+/- 1.0) is normally
desired for sugar-based syrups. Lower values
for some diet syrups can be specified. Check
with the syrup manufacturer if you are not sure.
12
Adjust BRIX
If BRIX is not within the proper range, adjust the
syrup/water mixture by opening or closing the
syrup valve, shown in Figure 32, and then
retest.
13
Clear hose
When BRIX measurement is complete, press
the valve on the bottom of the appropriate water
solenoid to flush out the hose before closing the
valve at the end of the hose.
14
Set product supply
valve
Turn product supply valve back to the (BAR-
REL) position for the barrel you tested. (See
Figure 31)
15
Replace access panel
Replace the hoses and the access panel.
Secure the panel with the two screws removed
in Step 2. This completes the procedure.
Table 26
Step
Action
Procedure
BRIX
SETUP
12:51P
MAR
04
#1
OFF
#2
OFF
BACK
BRIX
STOP
Splash
Panel
Retaining
Screws