Viper Service Manual
Publication Number: 621260373SER
- 24 -
© 2008-2012, IMI Cornelius Inc.
Error Status Menu
The Error Status menu, shown in Figure 17, displays any current errors contained
in the Error Messages List.
There are three types of errors that can be generated by the system. These error
types and a description of their meaning are listed in Table 5.
The possible messages from the control system and a description of the errors are
shown in Table 6. The button functions are described in Table 7.
Figure 17. Error Status Screen
Table 4
Button
Description
BACK
Returns the display to the Select menu
BRL
Displays the data for a single barrel, including Outlet Temperature,
Viscosity, if Refrigeration is On or Off, Average Ounces of product
dispensed per hour for the last three hours and Defrost Lock Time
until next defrost
UNIT
Displays the real time input voltage and frequency being supplied to
the unit and the low, high or both refrigeration pressures for the unit,
depending on the settings of the compressor sensors in the Unit
Data screen, as shown in Figure 36.
VER
Displays the version number of the UI, I/O, Motor and Status boards
installed in the unit
Table 5
Error Type
Description
System
A System error displays the same information across all barrels in the
unit.
Barrel
A Barrel error is limited to a specific barrel
Limp
A Limp error is an error that doesn’t prevent the unit from operating,
but limits functionality.
ERROR
STATUS
12:51P
MAR
04
#1
MOTOR
PWR
COMP
HIGH
BACK