background image

Installation, Operation and 

Maintenance Manual

ScaleStop Residential Systems

Chemical Free, Salt Free Scale Prevention

NSS-744R
NSS-844R
NSS-948R

NSS-1054R
NSS-1252R

6586 Hypoluxo Road, Suite 362

Lake Worth, FL 33467

(800) 783-0310

email: [email protected]

web: www.nextfiltration.com

© 2006-2010 next filtration technologies inc.

Summary of Contents for NSS-1054R

Page 1: ...ntial Systems Chemical Free Salt Free Scale Prevention NSS 744R NSS 844R NSS 948R NSS 1054R NSS 1252R 6586 Hypoluxo Road Suite 362 Lake Worth FL 33467 800 783 0310 email info nextfiltration com web www nextfiltration com 2006 2010 next filtration technologies inc ...

Page 2: ...0 12 Systems 2006 2010 next filtration technologies inc 2 document NSS 7 12 RES IOM pdf Table of Contents Introduction 3 System Overview 4 System Specifications 5 Cautions 6 Notes to the Installer 6 Installation and Start Up 7 Note to the Homeowner 8 Warranty 9 10 ...

Page 3: ...ssolved hardness does Therefore the problem of internal build up of scale in pipes water heaters and on fixtures and glass is greatly reduced ScaleStop is not a water softener Low or phosphate free cleaning products are recommended to achieve optimum results Modern surfactant or detergent based liquid soaps are preferred over old fashioned caustic solid soaps Unlike softened water Scalestop treate...

Page 4: ...2010 next filtration technologies inc 4 document NSS 7 12 RES IOM pdf Tank Head Media Tank System Overview CK V3007 02 1 Brass Sweat Fitting CK V3007 1 PVC Male NPT Elbow Assy CK V3006 Bypass Assy CK V3191 01 Bypass Elbow Assy Typical Connection Fittings Optional Connection Fittings ...

Page 5: ...ut Iron Manganese and Copper on the next page a b c e d Mechanical Specs 744 844 948 1054 1252 Max Service Flow gpm 10 12 16 20 30 Dry Weight lbs 22 25 29 35 43 Service Weight lbs 80 97 129 168 235 Dimensions nominal inches a 48 5 48 5 52 5 59 5 56 5 b 46 46 48 57 54 c 7 8 9 10 12 d 2 5 2 5 2 5 2 5 2 5 e 3 0 3 0 3 0 3 0 3 0 Using ScaleStop with other water treatment equipment Due to the unique pro...

Page 6: ...the water supply is from a private well confirm that the levels of iron Fe and manganese Mn are less than 0 3 mg L and 0 05 mg L respectively Copper should be less than 1 3 mg L Copper Copper usually originates from new copper plumbing upstream of the ScaleStop system If this condi tion exists we recommend waiting 3 4 weeks before placing the system in operation This will allow the copper surfaces...

Page 7: ...steady stream of water comes out of the outlet port 6 Connect the Outlet of the ScaleStop system to the cold water supply to the home 7 Open the supply valve to the ScaleStop system 8 Open faucets downstream from the ScaleStop system to relieve any air 9 Check for leaks Repair as needed 10 The system is now ready for service IN Cold Water OUT ScaleStop Treated Water Figure 1 844 shown with optiona...

Page 8: ...hwasher should be greatly reduced We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50 as com pared to hard water use Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting The use of a rinse aid may be advised Shower doors and tiles should have reduced spot ting When water...

Page 9: ...ial cleaning ScaleStop should keep it clean We also recommend that you drain your water heater tank This should be done 30 to 60 days after ScaleStop is installed and again in one year This is a good practice that can dra NBUJDBMMZ JODSFBTF UIF MJGF PG ZPVS XBUFS IFBUJOH BQQMJBODF G ZPV IBWF BO FMFDUSJD iUBOL UZQFw water heater for optimum results and higher efficiency we recommend you change the ...

Page 10: ...nformation including model number serial number and date of installation must be provided for any claims pertaining to equipment in warranty FGFDUJWF QBSUT BSF TVCKFDU UP JOTQFDUJPO CZ FJUIFS FYU JMUSBUJPO 5FDIOPMPHJFT OD PS BOZ BVUIP SJ FE SFQSFTFOUBUJWF CFGPSF GJOBM DPNNJUNFOU PG XBSSBOUZ BEKVTUNFOU JT NBEF 8 Next Filtration Technologies Inc reserves the right to make changes or substitutions in...

Page 11: ...y registration below in order to insure that we have documentation showing that you have purchased the system and that a qualified technician installed it The information provided will be kept in strict confidence and will never be available to marketing companies 1MFBTF EFUBDI UIF TFDUJPO CFMPX GJMM PVU UIF MJNJUFE JOGPSNBUJPO BOE TFOE JU BMPOH XJUI B DPQZ PG your receipt to Next Filtration Techn...

Page 12: ... 2006 next filtration technologies inc document NSS 7 12 RES IOM pdf ...

Reviews: