Teledyne Continental Motors, Inc.
TM
Non-Overhaul Removal and Replacement
IOF-550 Permold Series Engine Maintenance Manual
10-37
1 April 2007
15.
Secure the connector with the two fasteners and torque according to Appendix B.
16.
Safety wire the connector fasteners according to Appendix C.
17.
Install a 120 lb. cable tie around the connector and associated safety tab to secure the
tab as shown in Figure 10-34 and Figure 10-35. Trim the excess length from the cable
tie after tightening.
18.
For proper operation of the engine, route, clamp, support, and protect the wires in the
engine low voltage harness in a manner to prevent chafing, fretting, and wear of the
lead wires. Route and secure the harness according to Appendix C, “Harness
Routing” Instructions.
19.
Perform a FADEC Level I Diagnostics according to instructions in Chapter 8,
Troubleshooting.
20.
Perform an “Engine Operational Check according to instructions in Chapter 6,
Operational Performance Checks.
Figure 10-34.
ECU Connector
Figure 10-35.
SSA Conditioner Connector
10-6.2. Ground Strap Removal
Procedure
1.
Disconnect electrical power.
2.
Removal bolts and washers from ECU and airframe ground points.
3.
Remove ground strap.