CDD-562L/564 Demodulator with IP Module
Revision 2
Appendix D
MN/CDD564L.IOM
D–22
D.4.1.5 Operations and Maintenance Commands and Queries
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Base Modem Boot
From
BBI=
1 byte value
0,1,2
Command or Query.
The binary image, which will be used by the base modem, to boot with, where:
0 = Latest
1 = Image in Slot# 1
2 = Image in Slot#2.
Example: <1/BBI=0
BBI=
BBI!
BBI?
BBI=x
(see Description of Arguments)
Boot From Software
Image
BLI=
1 byte, value of
0,1,2
Command or Query.
Image which will be used the next time the system is booted, where:
0 = Latest
1 = Bulk Image # 1
2 = Bulk Image # 2
Example: BLI=1 (which is Image #1 active)
BLI =
BLI!
BLI?
BLI =x
(see Description of Arguments)
Codecast Multicast
Address
CCA=
Multicast IP
Address in
xxx.xxx.xxx.xxx
format
Command or Query.
Sets the Code cast multicast address, through which the modem can receive the software
updates via vLoad application. Only Multicast address in the range 224.xxx.xxx.xxx To
239.xxx.xxx.xxx are allowed. There are some reserved multicast addresses which cannot be
used.
This cannot be deleted.
CCA=
CCA!
CCA?
CCA=xxx.xxx.xxx.xxx
(see Description of Arguments)
Load Params from
permanent storage
LPS=
1-Byte value
1 – load
parameters
Command only.
Set to ‘1’ to load the system with parameters from permanent storage/flash. This may force
unit reboot, depending on the mode of operation.
LPS=
LPS!
N/A
LPS=x
(see Description of Arguments)
Param file image to
use
PFI=
1 byte, value of
1 or 3
Command or Query.
Image which will be updated the next time firmware is uploaded to the system:
1 = Param1
3 = Factory Default
To restore the Factory Defaults, set PFI=3 and issue RST to reset the box. This would
bring up the box with factory default configuration.
Example: PFI =1 (using param image on flash)
PFI =
PFI!
PFI?
PFI =x
(see Description of Arguments)
Summary of Contents for Vipersat CDD-562L
Page 2: ......
Page 4: ...ii This page is intentionally blank ...
Page 24: ...CDD 562L 564 Demodulator with Optional IP Module Revision 2 Preface MN CDD564L IOM xxii Notes ...
Page 40: ...CDD 562L 564 Demodulator with IP Module Revision 2 Introduction MN CDD564L IOM 1 16 Notes ...
Page 206: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix A MN CDD564L IOM A 6 Notes ...
Page 216: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix C MN CDD564L IOM C 4 Notes ...
Page 254: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...