CDD-562L/564 Demodulator with IP Module
Revision 2
Updating Firmware
MN/CDD564L.IOM
5–4
5.3
Ethernet FTP Upload Procedure
5.3.1
Getting Started: Preparing for the Firmware Download
Step
Task
1
Connect the user PC to the CDD-56X
10/100 Ethernet
port either via a hub or a switch or
with a direct Ethernet cable connection, and connect the CDD-56X
Console
port (do
NOT
use the
Remote Control
port) to a serial port on the user PC using an adapter cable.
See
Figure 4-1.
2
Identify the product in use, its firmware number for download, and its version number.
The current product M&C version and/or firmware number can be viewed as follows:
•
Using the 10/100 Ethernet port, via HTTP and the IP Module Web Server Interface
–
first click the
Maint
(Maintenance) tab, and then select the
Unit Info
hyperlink. For
more information, see
Chapter 6. WEB SERVER (HTTP) INTERFACE.
•
Using the 10/100 Ethernet port, via Telnet and the IP Module Command Line Interface
(CLI)
– first type ‘
O
’ (for Operations and Maintenance) on the main page, and then
type‘
I
’ (for Unit Information). For more information, see
Chapter 7. IP MODULE – CLI
AND TELNET OPERATION
.
3
Create a temporary folder (subdirectory) on the user PC for the firmware archive download.
•
Drive letter “c:” is used in these examples. Any valid, writable drive
letter can be used.
•
Typical for all tasks: Type the command without quotes, and then press
Enter to execute.
There are several ways the user may create a temporary folder on a Windows-based PC:
A.
Use the Windows Desktop to create and rename the temporary folder.
•
Right-click anywhere on the Windows Desktop to open the popup submenu, and then
select
New > Folder
to create the temporary folder. The “
New Folder
” will be created
on the desktop.
•
Right-click on the “
New Folder
” and then select ‘
Rename
’ from the popup submenu.
Rename this folder to "
temp
" or some other convenient, unused name.
B.
Use Windows Explorer to create and rename the temporary folder.
•
Select
File > New > Folder
to create the temporary folder. The new folder will be
created in the active folder.
•
Right-click the “
New Folder”
folder name, and then rename this folder to "
temp
" or
some other convenient, unused name.
Summary of Contents for Vipersat CDD-562L
Page 2: ......
Page 4: ...ii This page is intentionally blank ...
Page 24: ...CDD 562L 564 Demodulator with Optional IP Module Revision 2 Preface MN CDD564L IOM xxii Notes ...
Page 40: ...CDD 562L 564 Demodulator with IP Module Revision 2 Introduction MN CDD564L IOM 1 16 Notes ...
Page 206: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix A MN CDD564L IOM A 6 Notes ...
Page 216: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix C MN CDD564L IOM C 4 Notes ...
Page 254: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...